Send Message
Guangzhou Xingjin Fire Equipment Co.,Ltd.

IG100 100% Pressurized Nitrogen Inert Gas Fire Suppression System Fire Suppression Pipe Network Type

Product Details:
Place of Origin: China
Brand Name: Xingjin
Certification: CAL,CMA,CNAS,ILAC-MRA,CCC
Model Number: QMH15/80, QMH15/90
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: negotiable
Packaging Details: plywood outer box with bubble bag or paper
Delivery Time: 10-15 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 300 sets per month
  • Detail Information
  • Product Description

Detail Information

Cylinder Volume: 80L, 90L Capacity: 14.25kg, 16.04kg
Pattern Of Extinguishing: Enclosed Flooding Agent: IG100 (100% Pressurized Nitrogen)
Working Prussure: 15MPa Color: Red
High Light:

Nitrogen Inert Gas Fire Suppression System

,

IG100 Gas Fire Suppression System

Product Description

80L 90L IG100 Nitrogen Fire Suppression Device Pipe Network Type Red

 

Description 

 

The IG100 nitrogen fire suppression system, also known as an inert gas system, is a type of fire protection system that utilizes nitrogen gas to suppress fires in enclosed spaces. Here's a description of the IG100 nitrogen fire suppression system:

  • Inert Gas Composition: The IG100 system uses nitrogen gas as the primary extinguishing agent. Nitrogen is an inert gas that occurs naturally in the atmosphere, making it non-toxic, non-corrosive, and environmentally friendly. It does not deplete the ozone layer or contribute to global warming.
  • Fire Suppression Mechanism: The IG100 system works by reducing the oxygen concentration in the protected space to a level where combustion is no longer sustainable. Nitrogen gas is discharged into the area, displacing the oxygen and creating an oxygen-deficient atmosphere that suffocates the fire.
  • System Activation: When a fire is detected, the IG100 system is activated, either manually or automatically. Activation can be initiated through heat or smoke detectors, flame detectors, or a manual release station. Once activated, the system releases nitrogen gas into the protected area.
  • Rapid Fire Suppression: The IG100 system acts quickly to suppress fires and limit their spread. The rapid discharge of nitrogen gas helps to reduce the oxygen concentration in the space, effectively extinguishing the flames and preventing re-ignition.
  • Applications: The IG100 nitrogen fire suppression system is commonly used in various applications, including data centers, server rooms, control rooms, archives, museums, and other critical facilities. It is particularly suitable for areas where water or other traditional extinguishing agents may cause damage to sensitive equipment or valuable assets.
  • System Components: The IG100 system typically includes nitrogen storage cylinders, a high-pressure piping network, pressure relief devices, discharge nozzles, and a control panel. The system is designed and installed based on specific fire protection requirements and in compliance with applicable codes and standards.
  • Safety Considerations: While nitrogen gas is generally safe for humans, the oxygen-deficient atmosphere created by the IG100 system can be hazardous. Proper safety measures, including warning signs and ventilation requirements, should be implemented to ensure the safety of personnel in the event of system activation.
  • Maintenance and Inspections: Regular maintenance and inspections are essential to ensure the proper functioning of the IG100 system. This includes checking the integrity of the piping network, ensuring proper pressure levels, and conducting functional tests of the control panel and detection devices. Maintenance should be carried out by qualified technicians following manufacturer guidelines.

It's important to consult with fire protection experts and adhere to local regulations and guidelines when designing, installing, and maintaining an IG100 nitrogen fire suppression system. Proper system design and professional installation are crucial to ensure the system's effectiveness in suppressing fires and protecting lives and property.

 

 

Parameters of Fire Suppression System

 

No. Specification Technical Parameter
1 Working Pressure 15Mpa
2 Device Model QMD15/80 QMD15/90
3 Capacity 80Ltr 90Ltr
4 Filling Capacity of Gas 14.25kg 16.04kg
5 Outside Diameter of Cylinder Φ279mm Φ325mm
6 Height of Cylinder 1578+73mm 1345+60mm
7 Spraying Time ≤10s
8 Max Filling Rate 0.178kg/L
9 Power DC24V/1.6A
10 Nitrogen Pressure of Driving Device 6.0±1.0Mpa(20)
11 Condition of Reserving Room for Container temperature: 0~50
12 Max Working Pressure 17.2Mpa
13 Min Working Pressure 13.6Mpa

 

 

 

Application of Fire Suppression System

 

Fire suppression systems are designed to detect, contain, and extinguish fires in buildings, vehicles, and other enclosed spaces. Here are some common applications of fire suppression systems:

  • Commercial Buildings: Offices, retail establishments, and warehouses all frequently have fire suppression systems installed. These systems are made to spot and put out fires in the early stages, stopping them from spreading and inflicting significant harm on equipment and property.
  • Data Centers: Data centers are particularly vulnerable to fire-related disasters since they store vital IT infrastructure. To prevent damage to delicate electronic equipment, fire suppression systems with clean agents, like FM-200 or Novec 1230, are frequently used in data centers.
  • Industrial Facilities: Industries that work with flammable hazardous materials include chemical plants, refineries, and manufacturing facilities. Specialized extinguishing agents are used by fire suppression systems created for specific settings to put out flames involving combustible liquids and gases.
  • Marine Applications: Ships and boats frequently have fire suppression systems fitted to prevent fires that might start as a result of electrical problems, engine problems, or other dangers. In enclosed areas like engine rooms, these systems make use of specialized chemicals that are safe to utilize.
  • Residential Homes: Residential fire suppression systems are becoming increasingly popular for homeowners who want to protect their families and property from fires. These systems are typically designed to detect and suppress fires in their early stages, preventing them from causing extensive damage.

In general, fire suppression systems are crucial for preventing the disastrous impacts of fires on people and property. To make sure they'll work in an emergency, they should be installed and maintained by trained experts. To achieve the highest level of safety, fire suppression systems should be utilized in conjunction with fire preventive strategies including routine fire drills, smoke detectors, and fire extinguishers.

 

 

Advantages

  • The number of fire extinguishing agent cylinders may be reduced by 25% to 50% when compared to the typical 15MPa system.

  • The building's occupancy and usage rates have both increased, and the between-cylinder space has been successfully decreased.

  • Pipelines and pipe fittings can be more affordably priced with a continuous 6MPa low pressure release.

  • A distance of 200 meters may be covered by the transfer of 6 MPa continuous release pressure, which is more durable and efficient.

  • The impact on workers at construction sites, machinery, and building structures will only be reduced and safety will increase with the release of the complete system under low pressure.

  • The external constant pressure reliever can only bear the pressure when the system is spraying, which is convenient for dis-assembly and maintenance and effectively reduces the failure rate of the system. 
  • After spraying, the system does not need to replace any parts, simple dis-assembly and secondary filling, the system can be quickly put into operation.
  • The opening area of the pressure-relief device is reduced. the input cost of the pressure-relief device is directly reduced, and the safety buckle is installed and arranged more simply.
  • Nitrogen fire extinguishing system(IG-100) can be widely used to make rapid response to fire, protect staffs on sites, sudden fire, important places sensitive to chemical reaction and effectively protect the safety of personnel and property.
  • As a fire extinguishing agent, nitrogen is not a mixed product. It can be directly extracted from the air and has low maintenance and filling costs. Additionally, there are no chemical reagent residues that may exist in the mixed gas, making it safe and reliable. Due to filling an inert gas without the need for secondary pressurization, filling is simple and fast, which can shorten the production and processing cycle of the product.

 

 

IG100 100% Pressurized Nitrogen Inert Gas Fire Suppression System Fire Suppression Pipe Network Type 0

 

 

Packages

 

We always place it into a wooden case after first packing it with polyfoam. At times, we will create a pallet for the goods in order to satisfy clients or meet safety requirements.

 


IG100 100% Pressurized Nitrogen Inert Gas Fire Suppression System Fire Suppression Pipe Network Type 1

 

 

 

 

Mimic Diagram

 

 

Single/Multiple cylinder(s) for multiple zone

 

 

IG100 100% Pressurized Nitrogen Inert Gas Fire Suppression System Fire Suppression Pipe Network Type 2

 

                 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                                      Single/Multiple cylinder(s) for one zone

 

IG100 100% Pressurized Nitrogen Inert Gas Fire Suppression System Fire Suppression Pipe Network Type 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

After-Sale Service

 

• We have an efficient sales and after sales team to promise slove all client's question in time.

• We provide 8×6 hrs technical support and service.

Get in touch with us

Enter Your Message

You Might Be Into These