Refillable and Durable FM200 Gas Cylinder Unit with Epoxy Coating for Fire Protection

Product Details

Place of Origin: Guangzhou,China

Brand Name: XINGJIN

Certification: GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1

Model Number: 40L 70L 100L 120L 150L 180Letc

Payment & Shipping Terms

Minimum Order Quantity: 10 set system

Price: $120

Packaging Details: Plywood outer box with bubble bag or paper

Delivery Time: 15-20days

Payment Terms: T/T, L/C

Supply Ability: 30000 sets per month

Get Best Price
Product Details
Highlight:

refillable inert gas cylinder

,

durable FM200 storage unit

,

FM200 fire suppression cylinder

Usage:
Store The Extinguishing Agent
Durability:
High
Storage Medium:
FM200, Hfc-227ea, Novec 1230 Etc.
Material:
Steel
Coating:
Epoxy Or Polyester Powder
Safety:
High
Capacity:
40-180L
Usage:
Store The Extinguishing Agent
Durability:
High
Storage Medium:
FM200, Hfc-227ea, Novec 1230 Etc.
Material:
Steel
Coating:
Epoxy Or Polyester Powder
Safety:
High
Capacity:
40-180L
Product Description

FM200 Heptafluoropropane gas cylinder


Product Introduction:
   Fire gas cylinders are mainly used to store heptafluoropropane (hfc-227ea/fm200), which is a clean gas chemical fire extinguishing agent with both chemical and physical fire-extinguishing functions. It is a colorless, odorless, low-toxic, non-conductive and pollution-free protected object, and will not cause damage to property or precision facilities. The utility model can reliably extinguish Class B and C fires and electrical fires with low extinguishing concentrations, and it has a small storage space, does not damage the ozone layer of the atmosphere, and meets environmental protection requirements.

The safety hazards of gas cylinders of poor quality that have not been replaced for many years:
  During long-term use, fire gas cylinders (such as heptafluoropropane fire extinguishing systems, high-pressure carbon dioxide fire extinguishing systems, 1G541 fire extinguishing systems, IG100 fire extinguishing systems, etc.) may become thinner due to corrosion caused by external contamination. They may also develop cracks due to moisture or other impurities inside the cylinder corroding the steel cylinder. If exposed to high heat, the internal pressure of the container will increase, posing a risk of cracking and explosion.
1. Rust on the exterior of the cylinder body causes the wall thickness to become thinner, posing a risk of leakage and explosion to the gas cylinder. In severe cases, it may lead to casualties.
2. Pressure drop inside the cylinder: Pressure drop inside the gas cylinder leads to insufficient pressure, which prevents the normal discharge of fire extinguishing agents and hinders the fire extinguishing efficiency.
3. The inner wall of the bottle is corroded and thinned, causing the leakage of the agent and making it impossible to extinguish the fire normally. In severe cases, there is a risk of explosion.
 

  To ensure the best quality of fire gas cylinders, we strictly follow every manufacturing and testing procedure starting from raw materials. Conduct the final product inspection in accordance with the standards.

  We offer OEM and ODM services, designing and manufacturing according to customers' requirements

  Quality and Safety: We have passed the ISO9001:2000 management system and can provide self-inspection reports or. Provide third-party test certificates according to customer requirements.

 

Refillable and Durable FM200 Gas Cylinder Unit with Epoxy Coating for Fire Protection 0




Pipeline series cylinder dimensions:
 

Specification inner diameter Bottle thread Valve outlet aperture Bottle height Bottle + container valve height Total height of bottle + container valve + solenoid valve
40L*5.6MPa ø300 M80*2 50 757±15 897±15 1057±15
70L*5.6MPa ø350 M80*2 50 898±10 1038±10 1198±10
100L*5.6MPa ø350 M80*2 50 1213±10 1353±10 1513±10
120L*5.6MPa ø350 M80*2 50 1414±10 1554±10 1714±10
150L*5.6MPa ø400 M80*2 50 1395±10 1535±10 1695±10
180L*5.6MPa ø400 M80*2 50 1630±10 1770±10 1930±10
70L*17.2 ø267 PZ56 32 1499±10 1679±10 /
90L*17.2 ø325 PZ56 32 1420±10 1600±10 /
120L*17.2 ø325 PZ56 32 1835±10 2015±10 /

 

Specification inner diameter Bottle thread Valve outlet aperture Bottle height Bottle + container valve height
80L*17.2MPa ø279 M30*1.5 14 1578±73 1738±73
80L*23.2MPa ø279 M30*1.5 14 1610±70 1770±70
80L*36.6MPa ø267 M30*1.5 14 1770±10 1930±10
90L*17.2MPa ø325 M30*1.5 14 1345±60 1505±60
140L*23.2MPa ø356 M30*1.5 14 1825±20 1985±20
140L*36.6MPa ø356 M30*1.5 14 1825±20 198



The inspection and inflation process of fire protection gas cylinders
1. Registration of gas cylinder numbers, marking and identification of gas cylinders, condition inspection, and treatment of residual gases inside the cylinders
2. Disassembly, inspection and cleaning of the bottle head valve
3. Rust removal treatment of the inner and outer surfaces of gas cylinders, appearance inspection, and sound inspection
4. Inspection of the bottle mouth thread
5. Internal inspection of gas cylinders, weight and volume measurement, and liquid pressure resistance test
6. Wall thickness measurement and strength verification, internal drying treatment of gas cylinders
7. Maintenance and assembly of the bottle head valve
8. Air tightness test and pressure resistance strength test
9. Inspection and installation of bottle caps
10. Spray, print, fire inspection marks, and spray inspection color codes. 11. Issue inspection reports and store qualified gas cylinders in the warehouse

Packaging and transportation of gas cylinders:
Packaging:
  The gas cylinders will be carefully packaged to ensure safe delivery and handling. The packaging will include the following materials: heavy-duty cardboard boxes, foam packaging, protective foam, and instructions
Transportation:
  We offer global shipping for our gas cylinders. The following transportation methods are available for selection:
  All goods will be sent using reliable and trustworthy express delivery services to ensure timely and safe delivery. Once their order is dispatched, the customer will receive a tracking number via email.

Special handling instructions:
  If your goods have any special handling instructions, please contact us at least 24 hours before your order is dispatched. We will do our best to meet your requirements.
Refillable and Durable FM200 Gas Cylinder Unit with Epoxy Coating for Fire Protection 1
FAQ:

Q: Do you offer other types of fire protection equipment?
A: We offer a full range of FM200 fire protection products, including but not limited to ducted, cabinet, suspended, and cabinet-mounted FM200 systems, IG systems, fire alarms, ventilation systems, and more.


Q: Can you design a complete firefighting system for my factory?
A: Yes. Provide us with the size and area of ​​your factory, and we will have a professional designer provide you with excellent advice.


Q: Can you OEM and establish your own brand?
A: Yes, we offer OEM and ODM services, and you can also establish your own brand on your products.


Q: Can you produce firefighting cans with specific spray paint dimensions?
A: Yes, we are both a manufacturer and a trading company. We have our own factory and welcome your inquiries.