logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. Company Profile
products
Home > products > Fire Dampers > Spring Assisted Self Closing Fire Damper and Fire Smoke Damper with 150℃ Option in Cold Rolled Steel

Spring Assisted Self Closing Fire Damper and Fire Smoke Damper with 150℃ Option in Cold Rolled Steel

Product Details

Place of Origin: Guangzhou,China

Brand Name: XINGJIN

Certification: GSG\TUV

Model Number: FHF-W-K

Payment & Shipping Terms

Minimum Order Quantity: 50 set system

Price: Pricing based on quantity

Packaging Details: Plywood outer box with bubble bag or paper

Delivery Time: 15-20 working days after payment or receipt of L/C

Payment Terms: T/T,L/C

Supply Ability: 30000set/month

Get Best Price
Product Details
Highlight:

Spring Assisted Fire Damper

,

Cold Rolled Steel Fire Damper

,

Self Closing Fire Damper

Mountingstyle:
Flanged Or Sleeve
Material:
Galvanized Steel
Color:
Silver
State:
Normally Open
Finish:
Primer Coated Or Painted
Weight:
Varies By Size And Material
Type:
Easy To Install
Function:
Smoke Exhaust/ventilation
Warranty:
1 Year
Fireresistancerating:
Up To 3 Hours
Airflowcontrol:
Modulating Or On/Off
Size:
Customizable
Design Style:
Modern
Bladetype:
Single Or Multiple Blades
Temperaturerating:
Up To 250°F (121°C)
Mountingstyle:
Flanged Or Sleeve
Material:
Galvanized Steel
Color:
Silver
State:
Normally Open
Finish:
Primer Coated Or Painted
Weight:
Varies By Size And Material
Type:
Easy To Install
Function:
Smoke Exhaust/ventilation
Warranty:
1 Year
Fireresistancerating:
Up To 3 Hours
Airflowcontrol:
Modulating Or On/Off
Size:
Customizable
Design Style:
Modern
Bladetype:
Single Or Multiple Blades
Temperaturerating:
Up To 250°F (121°C)
Product Description
Spring-Assisted Self-Closing Fire Damper — 150℃ Option / Cold Rolled Steel

This fire damper is designed for through-wall pipes in ventilation and air conditioning systems that require fire protection. The valve operates automatically under the action of the blade gravity or spring force, with no external power supply required.

Product Parameters
Product Name Classification Model Nominal Diameter (DN) (mm) Nominal Pressure (PN) (MPa)
Gravity Fire Damper Fire damper 800 × 500 DN63 35.7
800 × 320 DN63 33.7
1000 × 320 DN64 39.7
1000 × 400 DN65 40.7
1000 × 500 DN66 41.7
1000 × 1000 DN69 44.7
1250 × 400 DN71 46.7
1250 × 800 DN74 49.7
1250 × 1250 DN76 51.7
1500 × 320 DN77 52.7
1500 × 500 DN79 54.7
1500 × 1000 DN82 57.7
Fire and Smoke Exhaust Valves

Fire valves are used to block the passage of smoke and flames from a fire area and to meet the requirements of fire stability and fire integrity within a specified period of time. Our company has absorbed advanced production technologies from both domestic and international sources and combined them with years of research and development on fire valves to optimize the design and improve the airtightness and flexibility of the valve body. This product has been tested and approved by the National Fire Equipment Quality Inspection Center.

When a building catches fire, flames can spread rapidly along the ducts of ventilation and air conditioning systems, causing significant losses in many cases. To minimize fire-related losses, effective fire prevention and smoke control measures must be taken to control the spread of fire. The reasonable installation of fire dampers in ventilation, air conditioning, and smoke control systems plays an important role.

Fire damper product diagram showing valve construction and installation configuration
Product Types
Fire Damper Type

A fire damper is a device installed on the supply and return air ducts of ventilation and air conditioning systems. It is usually in an open state, but when a fire occurs, it automatically closes when the gas in the duct reaches 70 ℃. Within a certain period of time, it can meet the requirements of fire resistance stability and integrity, playing a role in smoke isolation and fire prevention. This category includes various products such as gravity fire dampers, fire control valves, fire vents, airtight fire dampers, smoke dampers, and electronic self-control smoke dampers.

Smoke Exhaust Valve Type

The smoke exhaust valve is used on the smoke exhaust system pipeline or at the suction port of the smoke exhaust fan. It is usually in a closed state. When a fire occurs, the valve is manually or automatically opened through a fire alarm signal. According to the system function, it cooperates with the smoke exhaust. When the temperature of the smoke in the pipeline reaches 280 ℃, it automatically closes and can meet the requirements of fire resistance stability and integrity for a certain period of time, playing a role in smoke isolation and fire resistance. This category mainly includes smoke exhaust fire dampers, plate type smoke exhaust vents (for ceilings), smoke exhaust vents for vertical shafts, and other products. Fire dampers and smoke exhaust valves are important components in ventilation, air conditioning, and smoke control systems.

Air Volume Control Valve

An air volume regulating valve, also known as an air damper, is an indispensable central air conditioning terminal accessory in ventilation, air conditioning, and air purification projects for industrial plants and civil buildings. It is generally used in air conditioning and ventilation system ducts to regulate the air volume of branch pipes, and can also be used for mixed regulation of fresh and return air.

Why Choose Us
Company advantages and certifications for fire damper manufacturing