Lastest company news about FM200 Fire Extinguishing System-Cabinet Model and Hanging Model 2019/07/02
FM200 Fire Extinguishing System-Cabinet Model and Hanging Model
This type included two models. One is called cabinet FM200 fire extinguishing system. Another one is named as suspension FM200 fire extinguishing system. The principle of fire suppression and performance can refer to pipe network model. All of them are totally same. But the discharge time would be less than 8 seconds after activation for this model. This type consists of: FM200 fire extinguishing device: FM200 storage cylinders and cylinder valve c/w pressure gauge and solenoid actuator assembled with high pressure hose and nozzle and pressure switch in one device as a entire fire extinguishing device. Fire detection system(control panel and detectors and alarm and indication unit and so on) Those two parts will compose one automatic system to protect the single zone. Here it should be one space or room or enclosure. Of course, there can be put with more than one device in one room if one device is not enough to cover there. Relatively, this model will protect little rooms or relatively bigger rooms regarding different size of the model. Meanwhile, on condition that the situation in the room, you can choose to mount the device on wall or ceiling if you choose hanging type. You can also choose to put one in the corner or beside the wall inside of room if you choose cabinet type. There is no need to make the deployment of pipeline because of small space. The released gas can permeate the space very quickly and protect the whole room.
Read More
Lastest company news about FM200 fire Extinguishing System-pipe Network Type 2019/06/28
FM200 fire Extinguishing System-pipe Network Type
  The principle of this system is that detectors will monitor the situation inside that space and keep contact with the control panel. It will send the signal to the panel if fire. The panel will trigger the solenoid actuator to open FM200 storage cylinder after time-delay. Later, FM200(hfc-227ea) gas will be discharged and permeate the whole protection zone in a very short time less than 10 seconds.    This type is composed of:    FM200 fire extinguishing device: FM200 storage cylinders and cylinder valve c/w pressure gauge and solenoid/manual/pneumatic actuator as main parts, and other mounting parts(clamp or cylinder frame and support) and manifold and high pressure hose and check valve and selector valve (conducting the flow of fire extinguishing agent or changing the flow direction) and nozzles(discharging fire extinguishing agent into different direction and making it rapidly diffuse the protection zone)     Pipeline: pipes and pipe fittings(conducting the flow of fire extinguishing agent)     Fire detection system(control panel and detectors and alarm and indication unit and so on)     Those three parts will comprise one complete system which can cover the whole space of one protection zone or multiple enclosures in one room(ceiling, raised floor and main space) or different rooms. There is a high flexibility to the application of this system. You can adjust the storage cylinders to satisfy the rooms with different size. Meanwhile, there is a better usage for multiple rooms but in one systems because of the deployment of pipeline. Moreover, the system can make the discharge on average after reasonable and professional system design. Obviously, the previous design and later installation would be relatively complicated for this model.
Read More
1 2 3 4 5 6 7 8 9 10 11