A fire breaks out in your server room. The fire alarm sounds. But instead of turning on the sprinklers, the system does something else. It releases a colorless, odorless gas — and the fire is out in seconds. Your servers keep running. No water damage. No downtime.
Why not water? Because water and electronics do not mix.
Water + Servers = Disaster
At first glance, water seems like a logical choice for firefighting. It’s cheap, readily available, and effective. But in a server room, water is not a solution — it is a secondary disaster.
| Water Damage | Consequence |
|---|---|
| Short circuits | Water conducts electricity, causing immediate server failure |
| Corrosion | Moisture leads to rust and long-term equipment degradation |
| Data loss | Hard drives and storage systems can be permanently damaged |
| Prolonged downtime | Full cleanup and replacement can take weeks |
| Secondary damage | Water spreads throughout the room, damaging unaffected equipment |
So What Should You Use?
The answer is a clean agent gas suppression system — and the global standard for server rooms and data centers is FM200 (HFC-227ea) .
Why FM200 Is the Right Choice
| Requirement | How FM200 Delivers |
|---|---|
| No water damage | FM200 is a gas — no liquid, no residue, no corrosion |
| Fast suppression | Discharges within 10 seconds — fire out before it spreads |
| Safe for electronics | Non-conductive, non-corrosive — servers remain operational |
| Safe for people | NOAEL at 9% — safe for occupied spaces during discharge |
| No cleanup | Gas simply ventilates away — no downtime |
How FM200 Extinguishes a Fire
FM200 works through two mechanisms:
Physical cooling — The gas absorbs heat from the fire
Chemical interruption — It breaks the combustion chain reaction
The result: The fire is extinguished in under 10 seconds — and your servers are completely unharmed.
What About Other Options?
| Alternative | Problem |
|---|---|
| Dry powder | Leaves corrosive residue, clogs fans, damages electronics |
| Foam systems | Messy cleanup, not suitable for electronics |
| Inert gas (IG) | Requires larger cylinders, may cause pressure concerns |
| FM200 | Clean, fast, residue-free — the proven standard |
A Real-World Scenario
A fire starts in a server rack. Without FM200, the fire would grow until an automatic suppression system activates — or worse, sprinklers flood the entire room. With FM200, the fire is detected, the system discharges, and the fire is extinguished within seconds. Your servers remain online, your business continues, and no one spends weeks cleaning up.
The Bottom Line
Data centers, server rooms, and telecom facilities around the world trust FM200 because it works. It is fast. It is clean. It leaves no damage — and it protects the equipment that keeps your business running.
Don’t let water destroy what fire started.
Choose XINGJIN FM200 — the proven protection your server room deserves.
About XINGJIN Fire:
XINGJIN Fire is a specialized manufacturer of FM200 systems, IG541 inert gas systems, IG100 pure nitrogen systems, Novec 1230 systems, high-pressure CO₂ systems, automatic fire suppression tubes, and ventilation equipment. Serving clients across the Middle East, Southeast Asia, East Asia, the Caribbean, and beyond.