Send Message
Guangzhou Xingjin Fire Equipment Co.,Ltd.

40L 4.2MPa Red Fm200 Automatic Fire Extinguishing System

Product Details:
Place of Origin: China
Brand Name: Xingjin / OEM
Certification: CAL,CMA,CNAS,ILAC-MRA,CCC
Model Number: QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: Plywood outer box with bubble bag or paper
Delivery Time: 10-15 working days
Payment Terms: L/C, D/P, T/T, Western Union, Paypal, Credit card
Supply Ability: 28000 sets per week
  • Detail Information
  • Product Description

Detail Information

Cylinder Volume: 40L, 70L, 90L, 100L, 120L, 150L, 180L Capacity Of Gas: 38kg, 66.5kg, 85.5kg, 95kg, 114kg, 142.5kg, 171kg
Pattern Of Extinguishing: Enclosed Flooding Agent: Hfc-227ea (FM200)
Working Pressure: 4.2MPa / 5.6MPa Color: Red
Discharge Time: ≤10s Power: DC24V/1.5A
Starting Mode: Automatic, Electrical Manual, Mechanical Emergency Manual Product Name: Fm200 Fire Suppression System
High Light:

Fm200 Automatic Fire Extinguishing System

,

40L Automatic Fire Extinguishing System

Product Description

Automatic Fm200 Fire Suppression System Without Pollution for Archive
 
Description
 

1.Quick fire suppression: The FM200 fire suppression system uses the clean agent HFC-227ea, which can swiftly put out fires and extinguish them, minimizing damage from fires.
2.No residue: Unlike conventional fire suppression systems, the FM200 fire suppression system leaves no residue after putting out the fire, preventing both environmental contamination and subsequent damage to property and equipment.
3.Safe and dependable: The FM200 fire suppression system offers a high level of safety and dependability, making it ideal for use in a variety of settings, including computer rooms, archives, museums, hospitals, libraries, and workplaces. It is safe to use when people are around and won't hurt them or the environment.

4.Simple to maintain: The FM200 fire suppression system just has to be regularly inspected and tested to maintain its integrity and functionality. To further increase the efficiency of fire prevention and control, it can also be combined with other safety devices like smoke detectors and fire alarms.


 
Parameters

      

NO. Specifications 4.2Mpa system
1 Capacity 40Ltr,70Ltr,100Ltr,120Ltr,150Ltr,180Ltr
2 Device model QMP40/4.2, QMP70/4.2, QMP100/4.2,QMP120/4.2, QMP150/4.2, QMP180/4.2
3 Filling pressure 4.2Mpa
4 Max filling rate 0.95kg/L
5 Discharge time ≤10s
6 Power DC24V/1.5A
7 Nitrogen driving device 6.0±1.0Mpa
8 Storage surroundings Temperature:-10~50℃
Relative humidity:≤97%
9 Proportion ≤800m²
10 Volume ≤3600m³
 

   

40L 4.2MPa Red Fm200 Automatic Fire Extinguishing System 0 

 


  
Components 


     

1. Mechanical parts, such as drive cylinders, container valves, pneumatic valves, high-pressure hoses, collecting pipes, and bottle racks and storage bottles. primarily utilized to store fm200 reagents
2. Electrical components, including a host, an alarm, an alarm bell, a temperature sensor, a smoke sensor, etc.
3. Pipe fittings, such as nozzles, flanges, elbows, and joints.

 

40L 4.2MPa Red Fm200 Automatic Fire Extinguishing System 1

40L 4.2MPa Red Fm200 Automatic Fire Extinguishing System 2
 
Application

The single zone pipe network fm200 fire suppression system is appropriate for a single protected zone with a volume and proportion of less than 3600 cubic meters and 800 square meters, respectively, as its name implies. The single zone pipe network fm200 fire suppression system can be utilized to defend several large and important areas, because of its characteristics and principles of putting off fire, such as the following

 

 

- Data and paper archives

 

- Switch gear rooms

 

- High-tech medical

 

- Textile manufacturing

 

- Library

 

- Electric utility facilities

 

- Media storage

 

- Cargo space

                                                                                               40L 4.2MPa Red Fm200 Automatic Fire Extinguishing System 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40L 4.2MPa Red Fm200 Automatic Fire Extinguishing System 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40L 4.2MPa Red Fm200 Automatic Fire Extinguishing System 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Packages

 

We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

 

                                                                                                            40L 4.2MPa Red Fm200 Automatic Fire Extinguishing System 6       

 

 

 

After-Sale Service


• We have an efficient sales and after sales team to promise slove all client's question in time.
• We provide 8×6 hrs technical support and service.
 

 

FAQ

 

Q1: Are you a manufacturer or a trading company?

A1: We are a manufacturer.

 

Q2: Is OEM products available?

A2: Yes, we welcome your own design and drawing.

 

Q3: Where is your factory? Can I visit it?

A3: Our factory locates in Shilou, Panyu, Guangzhou, Guangdong, China.

Of course yes. We always welcome and wait for your visit.

 

Q4: How can I get to your factory?
A4: Because of the convenient transportation here, you can take a taxi or come here by subway. If you come here by subway, you need to take the line four and get off at Shiqi station. Then walk out the station for taking No. 126 bus and get off at Yuexi station.


 

Get in touch with us

Enter Your Message

You Might Be Into These