Product Details:
Place of Origin: China
Brand Name: xingjin
Certification: CAL,CMA,CNAS,ILAC-MRA,CCC
Model Number: GQQ40/2.5, GQQ70/2.5, GQQ90/2.5, GQQ100/2.5, GQQ120/2.5, GQQ150/2.5, GQQ180/2.5
Payment & Shipping Terms:
Minimum Order Quantity: 1set system
Price: negotiation
Packaging Details: Plywood case,Paper carton
Delivery Time: 10-15 working days after payment or receipt of L/C
Payment Terms: L/C, T/T, D/P, Western Union,Paypal,Credit Card,Debit Card
Supply Ability: 300 sets per month
  • Detail Information
  • Product Description

Detail Information

Spraying Time: ≤10s Actuation: Automatic Or Manual
Pattern Of Extinguishing: Enclosed Flooding Printed Color: Silver(cabinet), Red(cylinder)
Working Pressure: 2.5MPa Capacity Of Gas: 38kg, 66.5kg, 85.5kg, 95kg, 114kg, 142.5kg, 171kg
High Light:

FM200 Agent Cabinet Extinguisher

,

100L Agent Cabinet Extinguisher

,

Single Cylinder Fire Suppression System

Product Description

 

100L FM200 Cabinet Extinguisher Single Cylinder with Two Nozzles

 

 

Description: 

  • The FM200 Cabinet Extinguisher is a specialized fire suppression system designed to protect enclosed spaces, such as server rooms, data centers, control rooms, and other critical equipment areas. It utilizes FM200, a clean and gaseous fire suppression agent, to swiftly and effectively extinguish fires without causing damage to sensitive equipment or leaving residue behind.
  • The cabinet extinguisher is housed within a sturdy and secure enclosure, typically made of steel or other fire-resistant materials. The cabinet is designed to contain the FM200 agent and associated components, ensuring their proper operation and protection from external factors.
  • The FM200 agent used in the cabinet extinguisher is a colorless, odorless, and electrically non-conductive gas. It works by interrupting the fire triangle—the combination of heat, fuel, and oxygen—by reducing the oxygen concentration in the protected area. This prevents the fire from spreading and extinguishes it rapidly. FM200 is also known for its rapid action and leaves no residue after discharge, making it ideal for areas with sensitive electronic equipment.
  • The cabinet extinguisher is equipped with a range of safety features and components to ensure its reliable operation. These may include pressure sensors, discharge nozzles, control valves, and a dedicated release mechanism. The system is typically linked to a fire detection system or control panel, which activates the extinguisher upon detecting fire-related conditions.
  • When the system is activated, the FM200 agent is released into the protected space within seconds. The agent disperses rapidly, filling the enclosure and effectively suppressing the fire. The extinguishing process is designed to minimize downtime and prevent further damage to critical equipment, allowing for quick recovery and continuity of operations.
  • The FM200 Cabinet Extinguisher is a highly efficient and environmentally friendly fire suppression system. It is recognized for its ability to suppress fires effectively, its compatibility with sensitive electronic equipment, and its clean and residue-free discharge. The cabinet design ensures easy installation, maintenance, and accessibility, making it an ideal choice for protecting valuable assets in enclosed spaces.

100L FM200 Agent Cabinet Extinguisher Single Cylinder W/2 Nozzles Fire Suppression System 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compositions:

  

An extinguishing mechanism and electrical components make up the entirety of a one-set system (the composition is shown in the illustration below).

 

One set of the cabinet type FM200 fire suppression equipment consists of FM200 agents, an FM200 cylinder, a hoop, a cabinet, a container valve, a solenoid actuator, a flexible hose (high pressure hose), nozzle(s), and pressure switch.

 

 

 

100L FM200 Agent Cabinet Extinguisher Single Cylinder W/2 Nozzles Fire Suppression System 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Applications:

 

   

A clean room, anechoic chamber, emergency power facilities, flammable liquid storage space, a data processing center, telecommunications facilities, process control, pricey medical equipment, industrial equipment, a library, a museum, and an art gallery, among other things.

 

The areas where fires are more likely to occur, such as the engine room, cargo hold, rolling mills, printing presses, oil switches, oil-immersed transformers, and production lines spraying paint, among other places.

 

 

100L FM200 Agent Cabinet Extinguisher Single Cylinder W/2 Nozzles Fire Suppression System 2

 

 

Parameter:

 

NO. Specifications Parameters
1 Cylinder capacity 40Ltr,70Ltr,90Ltr,100Ltr,
120Ltr,150Ltr,180Ltr
2 Device model GQQ40/2.5, GQQ70/2.5, GQQ90/2.5, GQQ100/2.5, GQQ120/2.5, GQQ150/2.5, GQQ180/2.5
3 Filling pressure 2.5MPa
4 Max filling rate 0.95kg/L
5 Discharge time ≤10s
6 Working temperature 0℃~50℃
7 Max working pressure 4.2MPa
8 Discharge pressure 5.6±0.28MPa
9 Proportion of protected zone ≤500m²
10 Volume of protected zone ≤1600m³
11 Actuation Automatic or manual start

 

 


Competitive Advantage:

   

The following is a brief overview of some of the advantages of using a cabinet fire suppression system:


1. Rapid response. There is no requirement for long-distance pipe transmission, allowing for the immediate release of FM200 gas into the protective zone. Its spraying cycle is under 8 seconds long. It will therefore take less time overall when the fire arises.

 

2. Installation is simple. Installing a cabinet system versus a pipe network system would be simpler in comparison. The only thing left to do is link it to one or more cabinet fire extinguishing systems after installing the control panels and electrical components. However, no more than 4 pieces of the control panel should be positioned in a single room due to the output current constraint.

 

3. Lower price. For the protective zone that only requires a single cylinder, the cost would undoubtedly be lower than for a pipe network type because there would be no need to factor in the cost of pipes, pipe fittings, or labor for this component.

 

After-Sale Service

-----------------------------------------------------------------------------------

• We pledge to promptly address all client questions thanks to our effective sales and after-sales teams.

• We offer technical support and service 8–6 hours a day.

100L FM200 Agent Cabinet Extinguisher Single Cylinder W/2 Nozzles Fire Suppression System 3

 

Get in touch with us

Enter Your Message