logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. Company Profile
products
Home > products > Foam Fire Suppression System > Rapid Fire Extinguishing High-Expansion Foam Fire Extinguishing Generator

Rapid Fire Extinguishing High-Expansion Foam Fire Extinguishing Generator

Product Details

Place of Origin: Guangzhou,China

Brand Name: XINGJIN

Certification: CCC,CAC,ROHS

Model Number: PSF-4

Payment & Shipping Terms

Minimum Order Quantity: 1 set

Price: Pricing based on quantity

Packaging Details: Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper

Delivery Time: According to product quantity

Payment Terms: L/C, T/T

Supply Ability: 30000set/month

Get Best Price
Product Details
Highlight:
Product Name:
High-expansion Foam Generator
Mixed Liquid Flow Rate:
2.4-4.75L/S
Inlet Pressure:
0.3-1.0MPa
Foaming Amount:
35-200m³/min
Foaming Ratio:
201-1000
Product Name:
High-expansion Foam Generator
Mixed Liquid Flow Rate:
2.4-4.75L/S
Inlet Pressure:
0.3-1.0MPa
Foaming Amount:
35-200m³/min
Foaming Ratio:
201-1000
Product Description

High-expansion foam generator


Product Introduction
  The PSF-4 high-expansion foam generator is one of the main devices in the high-expansion foam fire extinguisher system. This product has a large foaming capacity and is suitable for extinguishing various types of fires.

 

Working principle
  The water wheel is driven by a foam mixture at a pressure of 0.3 to 1.0MPa to rotate the Feng Lun. The mixture is sprayed in a mist form onto the foaming net through the nozzle, forming a film on the surface of the net. The wind blown onto the net by the wind wheel expands into a large number of bubbles, forming a high-expansion cheongsam that subuncovers or covers the surface of the burning object.

  The purpose of fire extinguishing is achieved by taking advantage of the blocking, cooling and suffocation effects of foam. In total flooding and local application high-expansion foam fire extinguishing systems, it is fixed in the protected area to achieve the purpose of fire suppression.

Main technical parameters
 

Model specification Mixed liquid flow rate
(L/S)
Inlet pressure
(MPa)
Foaming amount
(m³/min)
Foaming ratio
PFS-4 2.4-4.75 (0.3-1.0)MPa 35-200 201-1000


 

Installation

  • There must be no obstructions within 3 meters from the air inlet end of the foam generator.
  • There shall be no obstacles hindering the discharge of foam within 1 meter in front of the foaming net of the foam generator
  • Foam generators used in total flooding systems must be installed at a height higher than the designed height of the foam
  • The foaming net should face the protected area
     

Maintain self-cultivation

  • Clean the foaming net frequently. At no time should there be any debris on the foaming net
  • The foam generator should be thoroughly rinsed with clean water after each injection
  • The foam generator should be overhauled once a year. After the overhaul and assembly are completed, a water pressure test of 1.25MPa should be conducted for sealing. There shall be no leakage or obvious deformation at all parts and connection points.
  • When not in use, cover the equipment with a rainproof cloth to avoid wind and sun exposure and extend its service life


FAQ
Q1: Are you a manufacturer or a trading company?
A1: We are a manufacturer.

Q2: Is OEM products available?
A2: Yes, we welcome your own design and drawing.

Q3: Where is your factory? Can I visit it?
A3: Our factory locates in Shilou, Panyu, Guangzhou, Guangdong, China.
Of course yes. We always welcome and wait for your visit.

Q4: How can I get to your factory?
A4: Because of the convenient transportation here, you can take a taxi or come here by subway. If you come here by subway, you need to take the fourth line and get off at Shiqi station. Then walk out the station for taking No. 126 bus and get off at Yuexi station.