Ceiling Mounted FM200 Fire Suppression Unit - Space Saving Automatic Activation with 68℃ Activating Temperature

Product Details

Place of Origin: Guangzhou,China

Brand Name: XINGJIN

Certification: GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1

Model Number: XQQW8L/10L/16L/20L/30L/40L

Payment & Shipping Terms

Minimum Order Quantity: 5 set

Price: USD69-160/set

Packaging Details: Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper

Delivery Time: 15-20days

Payment Terms: T/T, L/C

Supply Ability: 30000set/month

Get Best Price
Product Details
Highlight:

FM200 ceiling fire suppression unit

,

hanging FM200 control panel system

,

space-saving FM200 fire suppression

Tank Size:
8Ltr, 10Ltr, 16Ltr, 20Ltr, 30Ltr
Storage Pressure:
1.6mpa
Maximum Working Pressure:
2.5mpa
Discharge Time:
≤10s
Maximum Filling Density:
1kg/L
Activating Temperature:
68℃
Ambient Working Temperature:
0℃~50℃
Tank Size:
8Ltr, 10Ltr, 16Ltr, 20Ltr, 30Ltr
Storage Pressure:
1.6mpa
Maximum Working Pressure:
2.5mpa
Discharge Time:
≤10s
Maximum Filling Density:
1kg/L
Activating Temperature:
68℃
Ambient Working Temperature:
0℃~50℃
Product Description

Wall-mounted FM200 Automatic Fire Suppression System


Description:

  Suspended heptafluoropropane fire extinguishing devices are a type of equipment that pre-assemble storage containers, container valves, nozzles, etc. into independent units that can be suspended (or fixed on the wall) and can automatically or manually start to discharge fire extinguishing agents during fire suppression. According to the installation method, it can be divided into: suspended type and wall-mounted type.    The selection can be made based on the spatial location of the protected area. The suspended heptafluoropropyl alkane fire extinguishing device operates accurately and reliably, with a short spray time, rapid fire suppression, simple construction and installation, low engineering investment, and does not occupy the ground area of the protected zone.

Name of fire extinguishing agent Heptafluoropropane
Chemical composition CF3CHFCF3
Conveying method Prefabricated Pipe network type
Assembly method Cabinet type Suspended type Internal storage pressure External storage pressure
Product display Ceiling Mounted FM200 Fire Suppression Unit - Space Saving Automatic Activation with 68℃ Activating Temperature 0 Ceiling Mounted FM200 Fire Suppression Unit - Space Saving Automatic Activation with 68℃ Activating Temperature 1

 

Ceiling Mounted FM200 Fire Suppression Unit - Space Saving Automatic Activation with 68℃ Activating Temperature 2

 

Ceiling Mounted FM200 Fire Suppression Unit - Space Saving Automatic Activation with 68℃ Activating Temperature 3

Construction method Flexible to install and takes up little space Independent gas cylinder room
Pharmaceutical storage pressure 2.5/1.6MPa 4.2/5.6MPa 0.3MPa
Danger of handling/long-term storage The risk of handling and long-term storage is relatively low, and the safety factor of storage detection is relatively high
Design selectivity Small area, low construction difficulty and movable Large area, multiple protective zones, conveying distance 30-80 meters Large area, multiple protection zones, and conveying distance up to 200 meters
Dosage of medicine For a single area It is used for combined distribution and in relatively small quantities
Advantages Takes up little space, is easy to install, has low construction costs and good fire extinguishing effects Multiple protection zones share the same agent, with low cost and good fire extinguishing effect
Application Computer rooms, distribution rooms, archives rooms, financial institutions, government units, oil depots, etc

 

Product features:
High fire extinguishing efficiency;No residue after fire extingvishing;No effect on electronic equipment.

 

Type:

  FM200 hanging fire extinguishing equipment is divided into two types: temperature induction and electromagnetic induction.
 

  The suspended HFC-227ea fire extinguishing device (fixed temperature) relies on the room-temperature glass bulb in the valve to expand and rupture during a fire, opening the valve to release the extinguishing agent.
 

  The suspended HFC-227ea fire extinguishing device (electromagnetic) consists of an extinguishing agent storage tank, electromagnetic drive components, nozzle, pressure display, and signal feedback components. It can be hung or fixed on a wall and is used in conjunction with alarm devices such as fire detectors, manual push buttons, alarm bells, sound alarms, and fire alarm controllers.

Ceiling Mounted FM200 Fire Suppression Unit - Space Saving Automatic Activation with 68℃ Activating Temperature 4
Suspended heptafluoropropane fire extinguishing device
(fixed temperature type)
Suspended heptafluoropropane fire extinguishing device
(electromagnetic type)


 

Specification parameters:

Suspended heptafluoropropane fire extinguishing device
(fixed temperature type)
Suspended heptafluoropropane fire extinguishing device
(electromagnetic type)
Storage bottle specification 8L,10L,20L,30L
Storage pressure 1.6mpa
Maximum working pressure 2.5mpa
The time of fire extinguishing agent discharge ≤10s
Maximum filling density ≤1150kg/m3
Temperature sensing element 68℃
Ambient temperature of the protected area O℃~50℃
Storage bottle specification 16L,20L,30L
Storage pressure 1.6mpa
Maximum working pressure 2.5mpa
The time of fire extinguishing agent discharge ≤8s
Maximum filling density ≤1150kg/m3
Device startup power supply DC24V/1.6A
Ambient temperature of the protected area +O℃~50℃

 

Device model Filling amount (kg) Maximum working pressure(Mpa) Storage pressure (Mpa) Maximum coverage(m³) Starting mode
XQQW8/1.6 8 2.5 1.6 11.11 Temperature sensor

Activating Temperature:
68℃
XQQW10/1.6 10 2.5 1.6 13.89
XQQW16/1.6 16 2.5 1.6 22.22
XQQW20/1.6 20 2.5 1.6 27.78
XQQW30/1.6 30 2.5 1.6 41.67
Device model Filling amount (kg) Maximum working pressure(Mpa) Storage pressure (Mpa) Maximum coverage
(m³)
Starting mode
XQQC16/1.6 16 2.5 1.6 22.22 Solenoid actuator

Starting power:
DC24V/1.6A
XQQC20/1.6 20 2.5 1.6 27.78
XQQC30/1.6 30 2.5 1.6 41.67

 


Ceiling Mounted FM200 Fire Suppression Unit - Space Saving Automatic Activation with 68℃ Activating Temperature 5

Activation Method:
Temperature Control: This fire extinguishing controller relies on the valve's temperature-controlled glass bulb to expand and rupture during a fire, achieving its extinguishing effect. At temperatures generally around 68°C, the bulb automatically ruptures and releases the fire extinguishing agent.

Electromagnetic: Electromagnetic control is primarily available in two control modes: automatic and manual.
 

Electromagnetic Automatic: This fire extinguishing controller is equipped with both a smoke detector and a temperature-controlled heat detector.
The controller features a control mode selector. When in the "Automatic" position, the controller operates in automatic mode. If only one detector generates a fire signal, the controller will emit an audible and visual fire alarm to notify the user of the abnormality without activating the fire extinguishing device to release the extinguishing agent.
If activation of the fire extinguishing device is absolutely necessary, press the "Emergency Start Button" to activate the device and release the extinguishing agent to extinguish the fire.
When both detectors simultaneously emit fire signals, the controller emits audible and visual fire signals, notifying personnel of a fire and urging them to evacuate the scene. It also issues a linkage command, shutting down connected equipment such as fans and fire dampers. After a 30-second delay, it issues a fire extinguishing command, activating the solenoid valve, opening the container valve, and releasing the fire extinguishing agent to extinguish the fire.
If, during the alarm process, the fire extinguishing device is no longer required to activate, the "Emergency Stop" button outside the protected area or on the control panel can be pressed to terminate the control extinguishing command, preventing the activation of the fire extinguishing device and releasing the fire extinguishing agent to extinguish the fire.

Manual Electrical Operation: When the control mode selector on the controller is in the "Manual" position, the fire extinguishing controller is in manual control.
In this case, when the fire detectors emit a fire alarm signal, the controller issues an audible and visual fire alarm signal without activating the fire extinguishing device.
After personnel have confirmed that a fire has occurred, they can press the "Emergency Start" button outside the protected area or on the controller panel to activate the fire extinguishing device, release the fire extinguishing agent, and extinguish the fire.
However, the alarm signal remains. Regardless of whether the device is in automatic or manual mode, pressing any emergency start button will activate the fire extinguishing device, release the fire extinguishing agent, and put out the fire.
At the same time, the controller will immediately enter the fire extinguishing alarm state.


 

FAQ:

Q: Are you a trading company or a manufacturing factory?

A:We are both manufacturers and trading companies. We have had our own factory for nearly 15 years and we provide better services to overseas customers.
 

Q: Can you do it for me?

A: We accept all OEM orders. Just contact us and provide your design plan, and we will offer you a reasonable price as soon as possible.
 

Q: How do you ensure product quality?

A: We have a TUV/SGS/ISO quality control system and strictly enforce it. We have a professional quality inspection team. Before packaging, each packaging worker will conduct the final inspection in accordance with the quality inspection instruction manual.
 

Q: Besides this product, do you have any other traditional fire-fighting equipment?

A: Of course, we have a complete range of professional fire extinguishing equipment, from sound and light alarms to windbreak and smoke exhaust valves, as well as fire extinguishing systems such as FM200, CO2, and Novec1230. Welcome your inquiries!
 

Q: What about the delivery time?

A: We will ship the goods within 10 to 15 working days after receiving the deposit, based on the minimum order quantity. Under normal circumstances, an order for a 20-foot container takes 30 to 35 days to complete.
 

Welcome to inquire about the specific delivery time based on your order quantity!

 



Why Choose Us
Ceiling Mounted FM200 Fire Suppression Unit - Space Saving Automatic Activation with 68℃ Activating Temperature 6