logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. company profile
Products
Home > Products > Fire Detection Tube > Flexible FM200 Fire Detection Tube with 25m Maximum Length 12.1Mpa Maximum Pressure and 170℃ Auto Burst for Automatic Fire Suppression

Flexible FM200 Fire Detection Tube with 25m Maximum Length 12.1Mpa Maximum Pressure and 170℃ Auto Burst for Automatic Fire Suppression

Product Details

Place of Origin: Guangzhou,China

Brand Name: XINGJIN

Certification: GSG\TUV\GB6653-2008

Model Number: WZ-Q/T-EZ6-XJ60;WZ-Q/T-EJ45-XJ60

Payment & Shipping Terms

Minimum Order Quantity: 100 set system

Price: Pricing based on quantity

Packaging Details: Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper

Delivery Time: 15-20days

Payment Terms: T/T, L/C

Supply Ability: 30000set/month

Get Best Price
Product Details
Highlight:

25m Maximum Length Fire Detection Tube

,

12.1Mpa Maximum Pressure FM200 Fire Suppression Tube

,

170℃ Auto Burst Automatic Fire Extinguisher Tube

Density:
1.05g/cm3 ±0.1g/cm3
Melting Point Temperature:
170℃±10℃
Nominal Working Pressure:
5.7Mpa
Maximum Working Pressure:
12.1Mpa
Operating Temperature Range:
(0~49)℃
Maximum Length Of Fire Detection Tube:
25m
Maximum Loading Factor:
0.6kg/L
Density:
1.05g/cm3 ±0.1g/cm3
Melting Point Temperature:
170℃±10℃
Nominal Working Pressure:
5.7Mpa
Maximum Working Pressure:
12.1Mpa
Operating Temperature Range:
(0~49)℃
Maximum Length Of Fire Detection Tube:
25m
Maximum Loading Factor:
0.6kg/L
Product Description

FM200 Fire Detectors/Fire detection tube


What is a fire detection tube?

Fm200(htc-227ea) is a kind of colorless and tasteless and non-corrosive and electricity-insulating gas without residue and pollution after extinguishing. And ODP of it is zero. It is a friendly-environment gas to be used for extinguishing. Also, because of such feature, it can be used in special place where electrical fire is easy to happen.

 

Through long detecting tube with gas and pressure inside, it can be an automatic fire extinguisher without any manual manipulation.

Flexible FM200 Fire Detection Tube with 25m Maximum Length 12.1Mpa Maximum Pressure and 170℃ Auto Burst for Automatic Fire Suppression 0 Flexible FM200 Fire Detection Tube with 25m Maximum Length 12.1Mpa Maximum Pressure and 170℃ Auto Burst for Automatic Fire Suppression 1 Flexible FM200 Fire Detection Tube with 25m Maximum Length 12.1Mpa Maximum Pressure and 170℃ Auto Burst for Automatic Fire Suppression 2

 
Products Features:
Applied to the relatively closed space effectively.
Full automatic heating start, no electricity.
Simple installation and maintenance.
Special for Electric Equipment.

Parameters of FM200 fire detection tube:

Specification Technical parameter
Type Fm200 direct type Fm200 indirect type
Capacity of agent 2kg, 3kg, 4kg, 6kg, 9kg, 12kg
Working pressure 2.5Mpa
Max working pressure 4.2Mpa
Working temperature 0-50℃
Density of unit volume 0.7kg/m3
Length of detecting tube 5m-25m
Length of releasing tube -- 0.5m-1.5m

 

 

Products Application:
  The temperature-sensing automatic fire extinguishing device has solved the long-standing fire prevention problem that has plagued the fire protection industry in Spaces prone to fire hazards such as electrical equipment, control boxes, and distribution boards. At present, this device has been widely applied in power plants, communications, radio and television, petrochemical, railway and other systems in China, accumulating a wealth of successful experience.
It is suitable for extinguishing fires in the following places:
  The microwave machine room, decimeter wave machine room, meter wave machine room, transformer and distribution room and uninterruptible power supply room within the radio and television transmission tower; The program-controlled switch room, control room and signaling transfer point room of the communication system; The control room, electronic equipment room, computer room, relay room and transformer and distribution room of the power plant; Cable crossing, dense and intermediate connection points, etc. Transformer and distribution cabinets, elevator control cabinets, wire and cable troughs or cable trays with trough boxes; Special or important cabinet equipment with relatively sealed enclosures in other places.
Types of fires applicable for extinguishing:
1. The automatic fire extinguishing device with carbon dioxide filled fire detection tubes can be used to fight the following fires:
Combustible gas fires where the gas source can be cut off before extinguishing the fire;
Class A, B and C liquid fires or fires involving fusible solids such as paraffin and asphalt;
Solid surface fires and deep-seated fires of some solids such as cotton, wool, fabrics and paper;
Electrical fire.
2. Automatic fire extinguishing devices with fire detection tubes filled with carbon dioxide shall not be used to fight the following fires:
Fires involving chemical products containing oxidants such as nitrocellulose and gunpowder;
Fires involving active metals such as potassium, sodium, magnesium, titanium and zirconium;
Fires involving metal hydrides such as potassium hydride and sodium hydride.

Flexible FM200 Fire Detection Tube with 25m Maximum Length 12.1Mpa Maximum Pressure and 170℃ Auto Burst for Automatic Fire Suppression 3

 
How does it work?
  The fire detector, originating in Europe, is a simple, low-cost, and highly reliable independent automatic fire extinguishing system. It does not rely on any power source; it operates solely on its own pressurized power. This system is primarily designed for enclosed spaces such as electrical control boxes and machine rooms. The fire detector fire extinguishing device consists of a pressurized fire detector connected to it, which detects the fire and delivers the extinguishing medium to the protected area through the fire detector itself (direct system) or nozzles (indirect system).
  The fire detector is a new product developed in the high-tech field, combining long-term leak resistance, flexibility, and effective temperature sensing. The main components of the fire detection system are designed and manufactured under a strict quality control system. This product can use various extinguishing media, such as dry powder extinguishing agents, HFC-227, HFC-236 (low pressure), and carbon dioxide extinguishing agents (high pressure).
  The fire detection device can instantly and effectively extinguish fires and has the following advantages:
★ Unique extinguishing effect, effectively extinguishing fires in their early stages. The device automatically activates upon contact with fire, requiring no power supply or manual operation.
★ Ideal for unattended equipment and locations requiring intensive protection.
★ Rapid detection response time, reducing losses caused by the spread of fire.
★The fire detection tube is unaffected by location and can be inserted into various complex flammable spaces or equipment.
 

Flexible FM200 Fire Detection Tube with 25m Maximum Length 12.1Mpa Maximum Pressure and 170℃ Auto Burst for Automatic Fire Suppression 4 Flexible FM200 Fire Detection Tube with 25m Maximum Length 12.1Mpa Maximum Pressure and 170℃ Auto Burst for Automatic Fire Suppression 5   This fire extinguishing system uses a pressurized non-metallic hose that automatically bursts within a certain temperature range, spraying extinguishing agent or transmitting fire signals. This hose is directly placed at the potential ignition point and acts as a fire detection element. At a temperature of 160°C, the hose automatically bursts due to internal pressure, creating a spray hole that directly sprays the extinguishing agent to the fire source.   
  The system responds quickly and accurately, releasing extinguishing agents more promptly and effectively, resulting in stronger targeted and effective fire suppression. It can quickly and effectively detect and extinguish fires in their initial stages, making it an early-stage fire suppression system. This represents a significant advancement compared to traditional fixed gas fire suppression systems and dry powder fire suppression systems, which only extinguish fires in entire rooms or large spaces after they have already spread.

  The fire detection tube is essentially a linear detector, capable of both detecting fire and releasing extinguishing agents. Due to the small amount of extinguishing agent used, it reduces pollution and damage to the surrounding environment, significantly lowering the cost of each firefighting operation.
  Installation is simple and it occupies minimal space.
  The simple design minimizes installation and maintenance costs. It is not fully submersible, so release will not harm personnel in the protected area.
  It will not cause false alarms or accidental releases due to oil, dust, etc.
  This device has no electrical components, and its operation is unaffected by vibration or impact. Because the fire detection tube is a flexible tube, it can be placed arbitrarily at various wiring locations. This feature fills the gap in existing fire protection products that cannot extinguish this type of fire source.
 
How to order?
  Contact us and we will provide you with our product models and specific information.
  Tell us the model you need, the model you require customization for, and the quantity, and we will provide you with a detailed quote.
  If you are unsure which model you need, please tell us your fire safety space information, and we have a dedicated designer to assist you.
  Finally, we also offer professional logistics to provide you with one-stop service.

 

FAQ:

Q: Are you a trading company or a manufacturing factory?

A:We are both manufacturers and trading companies. We have had our own factory for nearly 15 years and we provide better services to overseas customers.

 

Q: Can you do it for me?

A: We accept all OEM orders. Just contact us and provide your design plan, and we will offer you a reasonable price as soon as possible.

 

Q: How do you ensure product quality?

A: We have a TUV/SGS/ISO quality control system and strictly enforce it. We have a professional quality inspection team. Before packaging, each packaging worker will conduct the final inspection in accordance with the quality inspection instruction manual.

 

Q: Besides this product, do you have any other traditional fire-fighting equipment?

A: Of course, we have a complete range of professional fire extinguishing equipment, from sound and light alarms to windbreak and smoke exhaust valves, as well as fire extinguishing systems such as FM200, CO2, and Novec1230. Welcome your inquiries!

 

Q: What about the delivery time?

A: We will ship the goods within 10 to 15 working days after receiving the deposit, based on the minimum order quantity. Under normal circumstances, an order for a 20-foot container takes 30 to 35 days to complete.

Welcome to inquire about the specific delivery time based on your order quantity!

 


Why choose us?​
Flexible FM200 Fire Detection Tube with 25m Maximum Length 12.1Mpa Maximum Pressure and 170℃ Auto Burst for Automatic Fire Suppression 6