FM200 Fire Detection Tube with 25m Maximum Length 170℃ Auto Burst and 12.1MPa Maximum Pressure for Automatic Fire Extinguishing

Product Details

Place of Origin: Guangzhou,China

Brand Name: XINGJIN

Certification: GSG\TUV\GB6653-2008

Model Number: WZ-Q/T-QZ3-XJ60

Payment & Shipping Terms

Minimum Order Quantity: 100 set system

Price: Pricing based on quantity

Packaging Details: Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper

Delivery Time: 15-20days

Payment Terms: T/T, L/C

Supply Ability: 30000set/month

Get Best Price
Product Details
Highlight:

25m Maximum Length FM200 Fire Detection Tube

,

170℃ Auto Burst Fire Detector Tube

,

12.1MPa Maximum Pressure Automatic Fire Extinguishing Device

Density:
1.05g/cm3 ±0.1g/cm3
Melting Point Temperature:
170℃±10℃
Nominal Working Pressure:
5.7Mpa
Maximum Working Pressure:
12.1Mpa
Operating Temperature Range:
(0~49)℃
Maximum Length Of Fire Detection Tube:
25m
Maximum Loading Factor:
0.6kg/L
Density:
1.05g/cm3 ±0.1g/cm3
Melting Point Temperature:
170℃±10℃
Nominal Working Pressure:
5.7Mpa
Maximum Working Pressure:
12.1Mpa
Operating Temperature Range:
(0~49)℃
Maximum Length Of Fire Detection Tube:
25m
Maximum Loading Factor:
0.6kg/L
Product Description


FM200 Direct-type Fire Detector Tube​


Introduction:
  The temperature-sensing self-starting fire extinguishing device is a kind of advanced fire extinguishing device that has just been developed in China and abroad in recent years. It belongs to a fixed non-electric self-starting type fire extinguishing device. This type of fire extinguishing device does not require power supply or traditional fire detection and alarm equipment. The entire device consists only of a fire extinguishing agent storage cylinder and a flexible fire detection tube. The fire detection tube integrates fire detection, fire extinguishing device activation, and fire extinguishing agent release functions. The flexible fire detection tube can be conveniently arranged at the nearest location to each potential fire source. Once a fire occurs, the fire detection tube is heated and ruptures, immediately releasing the fire extinguishing agent for point-to-point fire suppression.
FM200 Fire Detection Tube with 25m Maximum Length 170℃ Auto Burst and 12.1MPa Maximum Pressure for Automatic Fire Extinguishing 0

Performance Characteristics:
  First, the fire extinguishing agent delivery tube has the functions of fire detection, fire extinguishing device activation, and fire extinguishing agent release, eliminating the need for fire alarm and detection devices, thereby reducing costs and installation difficulties, and greatly improving the reliability of the fire extinguishing device, avoiding the false operation of electrical control alarm components.

  Second, this device only implements full-coverage fire extinguishing for equipment that has already caught fire, and quickly extinguishes the fire in a point-to-point manner, changing the situation where traditional gas fire extinguishing systems extinguish the entire equipment space regardless of the size of the fire, resulting in slow detection response time and excessive use of fire extinguishing agents.

  Third, the fire detection tube can be laid inside equipment and instruments that may catch fire, enabling the fastest detection of fires and the fastest point-to-point fire suppression for only the burning parts, resulting in faster response time, less fire extinguishing agent consumption, lower costs, and greater environmental friendliness.

  From the above three characteristics of the temperature-sensing self-starting fire extinguishing device, it can be seen that it is a more scientific fire extinguishing method in terms of improving fire extinguishing efficiency, saving costs, and environmental protection compared to current fixed fire extinguishing devices, especially solid gas fire extinguishing devices.
FM200 Fire Detection Tube with 25m Maximum Length 170℃ Auto Burst and 12.1MPa Maximum Pressure for Automatic Fire Extinguishing 1

System Application Scope:
  The temperature-sensing automatic fire extinguishing device has solved the long-standing problem in the fire protection field regarding the prevention of fires in spaces such as electrical equipment, control boxes, and distribution boards that are prone to fire. Currently, this device has been widely applied in domestic systems such as power plants, communications, broadcasting and television, petrochemicals, railways, etc., and has accumulated a large amount of successful experience.

1. Suitable for extinguishing fires in the following places:
Microwave rooms, decimeter wave rooms, meter wave rooms, power distribution rooms and uninterruptible power supply rooms in radio and television stations; Switching exchange rooms, control rooms and signaling transfer point rooms of communication systems; Control rooms, electronic equipment rooms, computer rooms, relay rooms, power distribution rooms of power plants; Locations such as cable intersections, dense areas and intermediate joints; Power distribution cabinets, elevator control cabinets, cable trays with troughs or bridges; Special or important cabinet equipment with relatively enclosed enclosures in other places.

2. Types of fires that can be extinguished

2.1 The automatic fire extinguishing device filled with heptafluoropropane can be used to extinguish the following fires:
Flammable gas fires that can cut off the gas source before extinguishing;
Fire of Class A, B and C liquids or molten solids such as paraffin and asphalt;
Surface fires of solids and partial deep-position fires of cotton, wool, paper and other solid materials;
Electrical fires.

2.2 The automatic fire extinguishing device filled with heptafluoropropane shall not be used to extinguish the following fires:
Fires of chemical products containing oxidants such as nitrocellulose, gunpowder;
Fires of active metals such as potassium, sodium, magnesium, titanium, zirconium;
Fires of metal hydrides such as potassium hydride, sodium hydride.

FM200 Fire Detection Tube with 25m Maximum Length 170℃ Auto Burst and 12.1MPa Maximum Pressure for Automatic Fire Extinguishing 2

Main parameters of the fire probe tube:

 

Outer diameter Inner diameter Wall thickness Density Melting point temperature
Φ6mm Φ4mm 1.0mm±0.1mm 1.05g/cm3 ±0.1g/cm3 170℃±10℃
 

Device technical parameters:

Device type

Device release type

Nominal working pressure Maximum working pressure Operating temperature range The minimum amount of fire extinguishing agent required per unit volume The maximum length of the fire probe tube Maximum length of the release tube Maximum filling coefficient
Heptafluoropropane temperature-sensitive automatic fire extinguishing device Direct form 2.5Mpa 4.2Mpa (-10~50)℃ 0.7kg/m3 25m -- 1.12kg/L
 

Device type and model:

Device type Model specification Fire extinguishing agent filling volume(kg) Effective protection scope(m3) The maximum length of the fire probe tube(m) Maximum length of the release tube(m) Device Release Type
Heptafluoropropane temperature-sensitive automatic fire extinguishing device

WZ-Q/T-QZ3-XJ60

 

3 4.2 25 -- Direct form