logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. company profile
Products
Home > Products > Inert Gas Fire Suppression System > IG541 Inert Gas Fire Suppression System for Data Center Protection with 15MPa Working Pressure and Eco-Friendly Design

IG541 Inert Gas Fire Suppression System for Data Center Protection with 15MPa Working Pressure and Eco-Friendly Design

Product Details

Place of Origin: Guangzhou,China

Brand Name: XINGJIN

Certification: CCC,ROHS,CAC

Model Number: QMH15/80;QMH15/90

Payment & Shipping Terms

Minimum Order Quantity: 10 set system

Price: USD360-500/set

Packaging Details: Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper

Delivery Time: 15-20days

Payment Terms: T/T,L/C

Supply Ability: 30000 sets per month

Get Best Price
Product Details
Highlight:

Eco-Friendly IG541 Fire Suppression System

,

15MPa Inert Gas Fire Suppression System

,

Data Center Protection IG541 System

Agent:
IG55(50% Nitrogen, 50% Argon )
Package Size:
456.00cm * 450.00cm * 1354.00cm
Max Working Pressure:
17.2MPa
Color:
Red
Maximum Working Pressure:
23.3MPa
Working Pressure:
15MPa,20MPa
Agent:
IG55(50% Nitrogen, 50% Argon )
Package Size:
456.00cm * 450.00cm * 1354.00cm
Max Working Pressure:
17.2MPa
Color:
Red
Maximum Working Pressure:
23.3MPa
Working Pressure:
15MPa,20MPa
Product Description
IG541 Inert Gas Fire Suppression System
The IG541 Fire Suppression System is a high-performance, environmentally friendly inert gas fire protection solution designed for critical facilities. With its piping network distribution design, the system supports centralized gas storage and multi-zone protection, making it ideal for large or complex installations.
System Overview
IG541 is a clean inert gas mixture composed of nitrogen (N₂), argon (Ar), and carbon dioxide (CO₂). It extinguishes fire by reducing oxygen concentration to levels that no longer support combustion. The agent is non-toxic, non-corrosive, non-conductive, and leaves no residue, ensuring maximum safety for personnel and sensitive equipment with no post-discharge cleanup required.
Applications & Fire Types
Suitable Fire Classes:
  • Class A: Surface fires of combustible solids (wood, fiber materials)
  • Class B: Fires of combustible liquids (heptane, gasoline)
  • Class C: Gas fires (when gas source can be cut off)
  • Class E: Electrical equipment fires
Ideal Locations:
  • Data centers and server rooms
  • Telecom and communication rooms
  • Control centers and electrical rooms
  • Libraries, archives, and cultural relic storage
  • Power plants and generator rooms
  • Industrial equipment areas
IG541 Inert Gas Fire Suppression System for Data Center Protection with 15MPa Working Pressure and Eco-Friendly Design 0
System Components
The IG541 mixed gas fire suppression system consists of: extinguishing cylinder groups, pressure reducing devices, electromagnetic drive devices, high-pressure hoses, extinguishing agent one-way starting cylinder groups, safety pressure relief valves, selection valves, gas one-way valves, low-pressure relief high-seal valves, pressure signalers, sprinklers, high-pressure pipe valves, conduits, and high-pressure pipe fittings.
IG541 Inert Gas Fire Suppression System for Data Center Protection with 15MPa Working Pressure and Eco-Friendly Design 1
Technical Specifications
Gas Composition:
Main Component Nitrogen (N₂) Argon Gas (Ar) Carbon Dioxide (CO₂)
Purity Requirements >99.9% >99.9% >99.5%
Water Content <5ppm <4ppm <10ppm
Oxygen Content <3ppm <3ppm <10ppm
IG541 Inert Gas Fire Suppression System for Data Center Protection with 15MPa Working Pressure and Eco-Friendly Design 2
Operating Parameters:
Parameter 80L Cylinder 90L Cylinder
Operating Temperature 0-50°C 0-50°C
Nominal Working Pressure (20°C) 15 MPa 15 MPa
Maximum Working Pressure (20°C) 17.2 MPa 17.2 MPa
Storage Tank Capacity 12 m³ 13.5 m³
Extinguishing Concentration (Class A) 28.1% 28.1%
Design Concentration (Class A) 36.5% 36.5%
System Operating Voltage 220V AC, 24V DC
Startup Methods Electrical Automatic, Electrical Manual, Mechanical Emergency Start
Key Benefits
15MPa high-pressure system for stable and efficient discharge
Non-toxic and no residue, safe for occupied spaces
Non-conductive and non-corrosive, ideal for sensitive equipment
Piping network design for multi-zone protection
Automatic, manual, and emergency activation
Environmentally friendly and standards compliant
If you are looking for a reliable, eco-friendly fire suppression solution for data centers and mission-critical facilities, the IG541 piping network fire suppression system is your optimal choice.
Why Choose Our IG541 System
IG541 Inert Gas Fire Suppression System for Data Center Protection with 15MPa Working Pressure and Eco-Friendly Design 3
Our IG541 systems comply with GB25972-2010 standards and offer stable performance, low maintenance costs, and zero ozone depletion potential (ODP=0). They produce no greenhouse effect and provide a sustainable alternative to traditional clean agents such as FM-200.