logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. Company Profile
products
Home > products > Novec 1230 Clean Agent > High-Efficiency Cylinder Charging Unit with Digital Display and ±0.5% Filling Accuracy for Clean Agent Refilling Equipment

High-Efficiency Cylinder Charging Unit with Digital Display and ±0.5% Filling Accuracy for Clean Agent Refilling Equipment

Product Details

Place of Origin: Guangzhou,China

Brand Name: XINGJIN

Certification: CCC,CAC,ROHS

Model Number: XJ-QEO-006

Payment & Shipping Terms

Minimum Order Quantity: 1 set system

Price: Pricing based on quantity

Packaging Details: Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper

Delivery Time: According to product quantity

Payment Terms: T/T,L/C

Supply Ability: 3000set/month

Get Best Price
Product Details
Highlight:

High-Efficiency Fire Extinguishing Agent Filling Machine

,

Digital Display FK-5-1-12 Filling Equipment

,

6.0 MPa Filling Pressure Clean Agent Refilling System

Maximum Filling Pressure:
6.0 MPa
Drug Output Pressure:
0~3.6 MPa
Vacuum Degree:
≤ -0.09 MPa
Filling Density:
≤ 1420 Kg/m³
Filling Accuracy:
±0.5%
Ambient Temperature:
0~50℃
Power Requirements:
AC 220V,50Hz
Equipment Size:
720×800×1280 Mm (excluding Runner)
Maximum Filling Pressure:
6.0 MPa
Drug Output Pressure:
0~3.6 MPa
Vacuum Degree:
≤ -0.09 MPa
Filling Density:
≤ 1420 Kg/m³
Filling Accuracy:
±0.5%
Ambient Temperature:
0~50℃
Power Requirements:
AC 220V,50Hz
Equipment Size:
720×800×1280 Mm (excluding Runner)
Product Description
Product Overview

The FK-5-1-12 fire extinguishing agent filling machine is a high-precision, safety-controlled filling system designed for the installation, maintenance, and refilling of clean agent fire suppression systems. Equipped with a vacuum system, nitrogen pressure regulating module, pressure alarm system, and a reserved weight alarm interface, it ensures safe, stable, and accurate filling performance.

Technical Specifications
Max Filling Pressure 6.0 MPa
Agent Output Pressure 0–3.6 MPa
Vacuum Degree ≤ -0.09 MPa
Filling Accuracy ±0.5%
Nitrogen Regulating Range 0–10 MPa
Power Supply AC 220V / 50Hz
Thread Connection M22×1.5
Dimension 720×800×1280 mm
Applications
  • Data Center Fire Protection
  • Power & Substation Protection
  • Archive & Library Fire Protection
  • Industrial Fire Suppression
  • Fire Engineering Contractors
  • Fire Equipment Manufacturers
Equipment Valve Body Functions
F1 Pressure Reducing Valve Controls the pressure of nitrogen entering the system to ensure a stable and safe filling process.
F2 Pressure Relief Valve Releases excess pressure in an emergency to protect equipment and gas cylinders from high-pressure damage.
F3 Chemical Storage Valve Controls the flow of fire extinguishing agent from the agent storage tank to the filling cylinder.
F4 Nitrogen Storage Valve Controls the nitrogen gas from the storage tank into the equipment pipeline to provide pressure for filling the fire extinguishing agent.
F5 Gas Cylinder Valve Connects fire extinguishing agent cylinders and controls the opening or closing of the cylinder fluid channel.
F6 Vacuum Valve Opens or closes the extraction of air from the gas cylinder to reduce internal pressure and ensure the purity of the fire extinguishing agent.
F7 Valve Controls the flow of perfluorohexanone into the gas cylinder.
F8 Valve Controls access to gas cylinders.
F9 Valve Controls the passage of nitrogen into the gas cylinder and provides pressure for the gas cylinder.
FK-5-1-12 fire extinguishing agent filling machine valve body diagram showing F1 through F9 valve components and connections
Frequently Asked Questions
Q: Are you a trading company or a manufacturer?

A: We are both a manufacturer and a trading company. We have owned our own factory for nearly 15 years and are committed to providing high-quality service to our overseas customers.

Q: Can you do OEM production?

A: We accept all OEM orders. Simply contact us with your design proposal, and we will provide you with a reasonable price as soon as possible.

Q: How do you ensure product quality?

A: We have TUV/SGS/ISO quality control systems and strictly adhere to them. We have a professional quality inspection team, and each packer conducts a final inspection according to the quality inspection instructions before packaging.

Q: What is the delivery time?

A: Depending on the minimum order quantity, we ship within 10–15 business days after receiving the deposit. 20-foot container orders typically take 30–35 days to fulfill.

Q: Besides filling machines, do you offer other conventional firefighting equipment?

A: Of course. We offer a full range of professional firefighting equipment, from sound and light alarms to smoke exhaust valves, as well as FM200, CO2, and Novec1230 fire suppression systems. Feel free to contact us!

Please inquire about the specific delivery time based on your order quantity.