EN54 Certified Fire Alarm System with Dual Power Supply and IP68 Rating for Reliable Fire Detection

Product Details

Place of Origin: Guangzhou,China

Brand Name: XINGJIN

Certification: CCC,CAC,ROHS

Model Number: CM1004

Payment & Shipping Terms

Minimum Order Quantity: 20 set system

Price: negotiation

Packaging Details: Plywood outer box with bubble bag or paper

Delivery Time: 15-20days

Payment Terms: T/T,L/C

Supply Ability: 30000set/month

Get Best Price
Product Details
Highlight:

EN54 certified fire alarm system

,

fire alarm system with dual power supply

,

IP68 rated fire detection system

Color:
Grey/Red
Mains Supply:
90 To 270VAC, 50Hz/60Hz
Battery Charge Current:
0.7A Maximum
Composition:
Converntional Control Panel/Light/Button/Alarm/Bell/Detector
Weight:
12.38kg
IP Rating:
Ip68
Light Intensity:
135cd
Color:
Grey/Red
Mains Supply:
90 To 270VAC, 50Hz/60Hz
Battery Charge Current:
0.7A Maximum
Composition:
Converntional Control Panel/Light/Button/Alarm/Bell/Detector
Weight:
12.38kg
IP Rating:
Ip68
Light Intensity:
135cd
Product Description
Complete Fire Alarm System
System Overview

This advanced fire alarm system features a modular design that integrates four-zone fire detection, automatic fire extinguishing control, and audible and visual alarm functions. The central control panel is EN54 certified and supports both smoke and heat detectors.

Solenoid Valve Drive

Equipped with 28VDC output for direct activation of gas-based fire suppression systems.

Dual Power Supply

Ensures continuous operation for at least 24 hours during main power failure.

Environmental Reliability

Designed to operate reliably in high-temperature and high-humidity conditions.

System Components

The complete system includes:

  • Central control panel with EN54 certification
  • Manual call points for emergency activation
  • Alarm bells and sirens for audible alerts
  • Emergency broadcast module for clear communication
  • Intelligent diagnostic function for continuous monitoring
  • Easy-to-install fire damper interfaces
System Wiring & Building Integration
EN54 Certified Fire Alarm System with Dual Power Supply and IP68 Rating for Reliable Fire Detection 0
Critical Wiring Requirements
  • Cables and wiring methods must comply with automatic alarm system technical requirements
  • Twisted-pair transmission cables must be used where specified
  • Wiring must meet minimum mechanical strength standards
  • Cables require protection via conduit, concealed wiring, or flame-retardant measures
  • Fire alarm cabling must be routed separately in dedicated cable shafts
  • Transmission networks cannot be shared with other systems

From an intelligent building perspective, automatic fire alarm systems and their linkage controls fall under building automation systems (BAS). These systems have specific management requirements, particularly for alarm and linkage wiring. Communication wiring for fire alarms operates as a standalone system, distinct from structured cabling used for general building automation.

As intelligent building technologies advance and fire alarm systems become more sophisticated, integration between the two is expected to increase. When selecting and designing fire alarm systems for intelligent buildings, special attention to interface compatibility ensures smooth integration during installation, operation, and ongoing use.

Customization & Support

We offer customized fire alarm solutions suitable for diverse applications including shopping malls, data centers, and petrochemical facilities. Our professional technical team provides comprehensive installation guidance and after-sales support to ensure reliable system performance.

Packaging & Shipping
Packaging Standards

All fire suppression system components are carefully packed using heavy-duty cardboard boxes, bubble wrap, and protective foam padding to ensure safe transport and handling.

Shipping Process

Shipments are arranged through reliable courier services to ensure timely and secure delivery. A tracking number is provided via email after order dispatch.

Special Handling Instructions

If special handling is required, please contact us at least 24 hours before your order is shipped. We will make every effort to accommodate your request.

Why Choose Our System
EN54 Certified Fire Alarm System with Dual Power Supply and IP68 Rating for Reliable Fire Detection 1 EN54 Certified Fire Alarm System with Dual Power Supply and IP68 Rating for Reliable Fire Detection 2

Thank you for choosing our fire alarm system. We are committed to providing you with reliable protection and peace of mind through advanced technology, comprehensive support, and proven performance in commercial and industrial applications.