Storage Medium: |
Novec 1230, FK-5-1-12, C6F12O |
Transport Package: |
Plywood Outer Box With Bubble Bag Or Paper |
Mini Order: |
1 Set |
Model: |
QMP40/4.2, QMP70/4.2, QMP100/4.2, ...... |
Product Name: |
Novec 1230 |
Material: |
Steel |
Safety: |
High |
Discharge Time: |
≤10s |
Filling Density: |
≤950kg/m3,≤1080kg/m3 |
Nitrogen Pressure Of Driving De Vice: |
6.0±1.0Mpa(20℃) |
Condition Of Reserving Room For Container: |
Temperature: -10~50℃, Relative Humidity: ≤97% |
Max Working Pressure: |
5.3Mpa/8.0Mpa |
Min Working Pressure: |
4.2Mpa/4.6Mpa |
Storage Medium: |
Novec 1230, FK-5-1-12, C6F12O |
Transport Package: |
Plywood Outer Box With Bubble Bag Or Paper |
Mini Order: |
1 Set |
Model: |
QMP40/4.2, QMP70/4.2, QMP100/4.2, ...... |
Product Name: |
Novec 1230 |
Material: |
Steel |
Safety: |
High |
Discharge Time: |
≤10s |
Filling Density: |
≤950kg/m3,≤1080kg/m3 |
Nitrogen Pressure Of Driving De Vice: |
6.0±1.0Mpa(20℃) |
Condition Of Reserving Room For Container: |
Temperature: -10~50℃, Relative Humidity: ≤97% |
Max Working Pressure: |
5.3Mpa/8.0Mpa |
Min Working Pressure: |
4.2Mpa/4.6Mpa |
Novec1230 (FK-5-1-12) pipe network automatic fire suppression system is a clean agent fire protection solution using an eco-friendly fluorinated ketone extinguishing agent. Specifically designed for data centers, telecom base stations, factory control rooms, hospitals, and commercial complexes, this system achieves full flooding discharge within 10 seconds. It leaves no residue, is non-conductive, and causes no harm to personnel or equipment, making it an ideal replacement for traditional Halon fire suppression systems.
High Temperature & Humidity Tolerance
Operates reliably at 0~50°C with relative humidity up to 97%, suitable for most climate conditions
Power Supply Compatibility
Powered by DC24V/1.6A, compatible with UPS and backup power systems commonly used in facilities.
Environmentally Compliant
Zero ODP and GWP of 1 with no halogen additives, aligning with CPCB guidelines for environmentally friendly fire extinguishing agents.
Local Certification Support
Cylinders, piping, and valves can be configured to meet BIS standards and local fire department technical review requirements.![]()
![]()
This system is widely recommended for the following commercial and industrial environments :
| Application | Specific Use Cases |
|---|---|
| Data Centers & IT Rooms | Third-party data centers and enterprise server rooms in Bangalore, Hyderabad, Pune, Mumbai, Chennai, Delhi-NCR |
| Telecom Infrastructure | BTS towers, switching centers, mobile communication hubs |
| Banks & Financial Institutions | State bank headquarters, data centers, vaults, ATM control rooms |
| Healthcare Facilities | Operating theaters, MRI rooms, pharmaceutical storage in large private hospitals and diagnostic centers |
| Manufacturing & Industrial Control Rooms | Central control rooms and electrical rooms in automotive, pharmaceutical, chemical, and textile plants |
| Metro & Rail Transit | Metro control centers, signal rooms, substations |
| Commercial Complexes & High Rise Buildings | Electrical rooms and server rooms in shopping malls, hotels, office towers |
| Energy & Power Facilities | Power plant control rooms, substations, battery rooms |
Fast Fire Suppression
Complete agent discharge in ≤10 seconds for rapid fire control, minimizing business interruption.
Clean & Residue Free
No cleanup required after discharge, preventing secondary damage to electronics or valuable assets.
Safe for Occupied Areas
Harmless at recommended design concentrations, with an adjustable time delay (approx. 2 minutes) for safe evacuation.
Environmentally Friendly
Zero ODP and GWP of 1 with no atmospheric lifetime restrictions, supporting green building initiatives.
Multi Zone Protection
A single system can protect multiple independent zones using selector valves, significantly reducing equipment costs.
Broad Fire Class Coverage
Effective against Class A (solids), Class B (liquids), Class C (gases), and electrical fires.
| Parameter | 4.2MPa System | 5.6MPa System |
|---|---|---|
| Filling Pressure | 4.2MPa | 5.6MPa |
| Max Protected Area per Zone | ≤800m² | ≤800m² |
| Max Protected Volume per Zone | ≤3600m³ | ≤3600m³ |
| Discharge Time | ≤10 seconds | ≤10 seconds |
| Filling Density | ≤0.95kg/L | ≤1.08kg/L |
| Operating Voltage | DC24V/1.6A | DC24V/1.6A |
| Nitrogen Driving Pressure | 6.0±1.0MPa (20°C) | 6.0±1.0MPa (20°C) |
| Cylinder Capacity | 40L / 70L / 100L / 120L / 150L / 180L | 70L / 90L / 120L |
| Max Working Pressure | 5.3MPa | 8.0MPa |
| Storage Temperature | 0~50°C | 0~50°C |
| Relative Humidity | ≤97% | ≤97% |
Agent Storage Cylinders – Pressure vessels containing Novec1230 agent
Nitrogen Actuation Cylinders – Releases the cylinder valve to discharge agent
Selector Valves – Enables multi-zone selective discharge
Pipe Network – High pressure galvanized steel pipes and fittings
Nozzles – Evenly distributes extinguishing agent throughout the protected area
Fire Alarm Control Panel – Detection, alarm, and actuation control
Detectors – Smoke and heat detection devices![]()
![]()
![]()
Engineering drawings compliant with electrical and fire safety standards
Technical documentation support for local fire department approval and commissioning
Local stock of common cylinder sizes and pipe fittings in Mumbai / Delhi / Bangalore
Remote commissioning guidance and on-site technical support
Engineer dispatch available for on-site system commissioning and operator training
Q: Does the system require local certification?
A: Main components can be configured to meet BIS and local fire code requirements. We provide technical documentation to assist with local approvals.
Q: How often do cylinders need inspection?
A: Hydrostatic pressure testing and air tightness inspection is recommended every 5-6 years. Follow local fire department guidelines for specific requirements.
Q: How to refill the agent after discharge?
A: Cylinders can be returned to us or authorized partners for refilling, or you may use qualified local refilling service providers.