Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582
Product Details
Place of Origin: Guangzhou,China
Brand Name: XINGJIN
Certification: CCC,CAC,ROHS
Model Number: XJ-QEO-006
Payment & Shipping Terms
Minimum Order Quantity: 1 set system
Price: Pricing based on quantity
Packaging Details: Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
Delivery Time: According to product quantity
Payment Terms: T/T,L/C
Supply Ability: 30000set/month
Applicable Fire Extinguishing Agent: |
Perfluorohexanone, Nitrogen |
Maximum Filling Pressure: |
6.0 MPa |
Nitrogen Decompression Range: |
0~10 MPa Adjustable (commonly Used: 4.2 MPa, 5.6 MPa) |
Drug Output Pressure: |
0~3.6 MPa |
Vacuum Degree: |
≤ -0.09 MPa |
Filling Pressure Alarm: |
0~10 MPa (adjustable, The Alarm Light Will Turn On When Reaching The Set Value) |
Filling Density: |
≤ 1420 Kg/m³ |
Filling Accuracy: |
±0.5% |
Ambient Temperature: |
0~50℃ |
Power Requirements: |
AC 220V,50Hz |
Equipment Size: |
720×800×1280 Mm (excluding Runner) |
External Connection Thread: |
Threads For Reagent Inlet And Outlet And Nitrogen Interface: M22×1.5 |
Applicable Fire Extinguishing Agent: |
Perfluorohexanone, Nitrogen |
Maximum Filling Pressure: |
6.0 MPa |
Nitrogen Decompression Range: |
0~10 MPa Adjustable (commonly Used: 4.2 MPa, 5.6 MPa) |
Drug Output Pressure: |
0~3.6 MPa |
Vacuum Degree: |
≤ -0.09 MPa |
Filling Pressure Alarm: |
0~10 MPa (adjustable, The Alarm Light Will Turn On When Reaching The Set Value) |
Filling Density: |
≤ 1420 Kg/m³ |
Filling Accuracy: |
±0.5% |
Ambient Temperature: |
0~50℃ |
Power Requirements: |
AC 220V,50Hz |
Equipment Size: |
720×800×1280 Mm (excluding Runner) |
External Connection Thread: |
Threads For Reagent Inlet And Outlet And Nitrogen Interface: M22×1.5 |
FM200 agent cylinder is a high-quality pressure vessel specifically designed for storing heptafluoropropane (HFC-227ea) fire extinguishing agent, serving as a core component of FM200 fire suppression systems. This FM200 storage cylinder is widely used in automatic fire extinguishing systems to provide reliable fire protection for data centers, telecommunication rooms, archives, and other critical facilities. Manufactured from high-quality pressure vessel steel, the cylinder offers excellent sealing performance and pressure resistance, ensuring the safety and stability of FM200 gas throughout storage and transportation.![]()
![]()
The FM200 (heptafluoropropane) agent cylinder is an indispensable component of clean agent fire suppression systems. The cylinder is strictly designed and tested in accordance with national pressure vessel standards and is refillable for cost-effective operation. FM200 agent itself is a colorless, odorless, and non-conductive liquefied gas that leaves no residue and causes no corrosion after discharge, making it highly compatible with precision equipment and valuable assets.
| Parameter | Value |
|---|---|
| Product Name | FM200 (Heptafluoropropane / HFC-227ea) Agent Cylinder |
| Suitable Media | Heptafluoropropane (HFC-227ea / FM200), Nitrogen |
| Appearance | Colorless liquefied gas (stored in pressure vessel) |
| Purity (by GC) | ≥ 99.9% |
| Moisture Content | ≤ 10 ppm |
| Acidity (as HF) | ≤ 3 ppm |
| Non-Volatile Residue | ≤ 0.05 mg/100ml |
| Material | High-Quality Pressure Vessel Steel |
| Ozone Depletion Potential (ODP) | 0 |
| Packaging | Cylinder / Storage Tank |
FM200 agent cylinders are widely used in conjunction with gas fire suppression systems in the following locations:
Data Centers and Server Rooms – Protects critical IT infrastructure with zero residue after discharge
Telecommunication Rooms and Program-Controlled Exchange Rooms – Suitable for precision electronic equipment environments
Archives and Museums – Protects valuable documents and artifacts with no corrosive residue
Libraries and Record Repositories – Safe for paper-based materials and digital media
Transformer Rooms and Switchgear Rooms – Specifically for electrical fires, non-conductive
Generator Rooms – Protects power generation equipment
Oil Depots and Chemical Warehouses – Liquid and solid surface fire protection
Financial Institutions and Government Facilities – Fire protection for critical locations
Broadcasting and Television Centers – Ensures safe operation of broadcasting equipment
Precision Instrument Rooms – Environments with equipment highly sensitive to residue![]()
High Purity (≥ 99.9%) – Ensures extinguishing efficiency and long-term system reliability
Ultra-Low Moisture Content (≤ 10 ppm) – Prevents formation of acidic byproducts, protecting system components
No Corrosive Residue – No damage to precision equipment or valuable assets after discharge; no cleanup required
Zero Ozone Depletion Potential (ODP = 0) – Does not harm the ozone layer
Non-Conductive – Safe for use on energized electrical equipment fires
Colorless and Odorless – Does not obstruct visibility during discharge, facilitating safe evacuation
Refillable and Reusable – Cost-effective, reducing long-term operating costs
Compliant with International Standards – Manufactured and tested to pressure vessel codes
Store in a cool, dry, and well-ventilated area
Avoid direct sunlight and high-temperature environments (recommended storage: -20℃ ~ +50℃)
Regularly inspect cylinder exterior, pressure gauge readings, and seal conditions
Avoid severe impact during filling, transport, and use
Ensure system design concentration is within safe limits during installation
A hydrostatic pressure test at 5.3 MPa is recommended every five years to verify cylinder safety
Q: What material is the FM200 agent cylinder made of?
A: The cylinder is manufactured from high-quality pressure vessel steel, offering excellent pressure resistance and corrosion protection for long-term safe use.
Q: Can the agent cylinder be reused?
A: Yes. After the FM200 agent is depleted, the cylinder can be returned to a professional filling station for cleaning and refilling, providing both environmental and economic benefits.
Q: Does FM200 have any environmental impact?
A: FM200 has an Ozone Depletion Potential (ODP) of zero, meaning it does not harm the ozone layer. However, its Global Warming Potential (GWP) is relatively high, so usage should be strictly controlled according to design specifications.
Q: Does FM200 produce toxic substances when extinguishing fires?
A: It is safe when used at normal design concentrations. However, when the agent concentration exceeds a certain level, it may produce trace amounts of HF (hydrogen fluoride), which can be effectively avoided or controlled through proper system design.
Q: Is the cylinder interface compatible with mainstream fire suppression systems?
A: Yes. The cylinder features a standardized interface design, compatible with most mainstream FM200 fire suppression systems for convenient installation.