logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. Company Profile
products
Home > products > NOVEC 1230 Fire Suppression System > Four Point Two MPa Novec1230 Gas Cylinder for Clean Agent Fire Extinguishing Equipment Protection

Four Point Two MPa Novec1230 Gas Cylinder for Clean Agent Fire Extinguishing Equipment Protection

Product Details

Place of Origin: Guangzhou, Guangdong, China

Brand Name: Guangzhou Xingjin Fire Equipment Co.,Ltd.

Certification: CCC,ROHS,CAC

Model Number: QMP40/4.2, QMP70/4.2, QMP100/4.2, ......

Payment & Shipping Terms

Minimum Order Quantity: 1 set system

Price: Pricing based on quantity

Packaging Details: Plywood outer box with bubble bag or paper

Delivery Time: 15-20days

Payment Terms: T/T,L/C

Supply Ability: 30000 sets per month

Get Best Price
Product Details
Highlight:

Four Point Two MPa Novec1230 gas cylinder

,

Novec1230 fire extinguishing equipment

,

Clean agent fire protection cylinder

Discharge Time:
≤10s
Storage Temperature:
-10~50℃
Material:
Steel
Min Working Pressure:
4.2Mpa/4.6Mpa
Max Working Pressure:
5.3Mpa/8.0Mpa
Discharge Time:
≤10s
Storage Temperature:
-10~50℃
Material:
Steel
Min Working Pressure:
4.2Mpa/4.6Mpa
Max Working Pressure:
5.3Mpa/8.0Mpa
Product Description

vessels of clean agent fire extinguishing systems, designed to safely store Novec1230 extinguishing agent. Manufactured from high-strength steel, these cylinders comply with NFPA 2001 and ISO 14520 international standards while also supporting alignment with Indonesian National Standards (SNI). They provide reliable agent storage solutions for data centers, telecommunications facilities, banks, hospitals, and industrial control rooms across Indonesia.


Why Choose Novec1230 Cylinders – Indonesia Market Adaptation



Adaptation Aspect Details
International & Local Standards Compliance Systems comply with NFPA 2001 and ISO 14520, with design and installation capable of meeting SNI requirements
Environmental Compliance Zero ODP, GWP < 1, and atmospheric lifetime of only 5 days, meeting Indonesia's green building and ESG commitments
HFC Phase-Down Resilience As a Kigali Amendment signatory, Indonesia faces HFC phase-down pressures; Novec1230 is not subject to such restrictions, offering a long-term reliable solution
Highest Personnel Safety Margin NOAEL of 10%, the highest among all clean agents, suitable for occupied spaces
Local Service Support Licensed fire engineering companies in Jakarta (e.g., PT Totalfire Indonesia) provide Novec1230 system design, installation, and maintenance services

Indonesia Typical Applications

Novec1230 cylinders are widely installed in the following Indonesian commercial and industrial facilities:



Application Typical Scenarios
Data Centers & Server Rooms Data centers and enterprise server rooms in Jakarta, Surabaya, Bandung
Telecommunications Facilities BTS sites, switching centers, communication hubs
Banks & Financial Institutions Bank data centers, trading system rooms, vaults
Healthcare Facilities Operating theaters, MRI rooms, pharmaceutical cold storage in major hospitals
Museums & Cultural Heritage Archive storage, museums, cultural heritage preservation sites
Industrial Control Rooms & Electrical Rooms Control rooms and electrical rooms in manufacturing, petrochemical, and power generation facilities
Commercial High-Rise Buildings Electrical rooms and UPS rooms in malls, hotels, office towers
Oil & Gas Facilities Refinery control rooms, offshore platform control rooms
Marine Vessels Ship engine rooms and cargo holds

Regulatory Note: Indonesian regulations require that generators, power distribution rooms, gas turbines, and other electrical installations in factories and commercial buildings be equipped with automatic fire suppression systems connected to automatic alarm systems. Clean agent gaseous systems, including Novec1230, are among the approved solutions.


Key Advantages

  • High-Strength Steel Construction
    Forged from high-quality carbon steel, available in both 25bar and 42bar working pressures, with maximum working pressures of 35bar and 60bar respectively

  • Various Capacity Options
    Available in 40L, 70L, 90L, 100L, 120L, 150L, and 180L to accommodate different system design requirements

  • Long-Term Reliability
    Following 3M's production exit, other approved FK-5-1-12 manufacturers offer equivalent agent quality and refilling services, allowing existing systems to continue operating without replacement

  • Safe & Reliable
    Each cylinder undergoes rigorous hydrostatic pressure testing and air-tightness inspection, fitted with rupture discs and pressure gauges for long-term storage safety

  • Refillable Design
    After agent discharge, cylinders can be returned to authorized refilling stations. Licensed fire engineering companies in Indonesia provide refilling and maintenance services


Technical Specifications



Parameter 25bar (4.2MPa) System 42bar (5.6MPa) System
Filling Pressure (20°C) 25bar 42bar
Max Working Pressure (50°C) 35bar 60bar
Filling Density ≤0.95kg/L ≤1.08kg/L
Operating Temperature 0~50°C 0~50°C
Relative Humidity ≤97% ≤97%
Material High Quality Carbon Steel High Quality Carbon Steel
Applicable Standards NFPA 2001, ISO 14520 NFPA 2001, ISO 14520

Indonesia Market Service Support

  • System design can reference NFPA 2001 and ISO 14520 standards with alignment to SNI requirements

  • Cylinders can be integrated with NFPA 72 fire alarm systems

  • Assistance in coordinating with Indonesian licensed fire engineering companies (e.g., PT Totalfire Indonesia) for installation and commissioning

  • Technical documentation support including system design drawings and commissioning guides

  • For existing Novec1230 systems, post-3M exit guidance includes: cylinder condition assessment, valve support evaluation, spare part availability review, and contingency plan development for refilling