Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582
Product Details
Place of Origin: Guangzhou, Guangdong, China
Brand Name: Guangzhou Xingjin Fire Equipment Co.,Ltd.
Certification: CCC,ROHS,CAC
Model Number: QMP40/4.2, QMP70/4.2, QMP100/4.2, ......
Payment & Shipping Terms
Minimum Order Quantity: 1 set system
Price: Pricing based on quantity
Packaging Details: Plywood outer box with bubble bag or paper
Delivery Time: 15-20days
Payment Terms: T/T,L/C
Supply Ability: 30000 sets per month
Discharge Time: |
≤10s |
Storage Temperature: |
-10~50℃ |
Material: |
Steel |
Min Working Pressure: |
4.2Mpa/4.6Mpa |
Max Working Pressure: |
5.3Mpa/8.0Mpa |
Discharge Time: |
≤10s |
Storage Temperature: |
-10~50℃ |
Material: |
Steel |
Min Working Pressure: |
4.2Mpa/4.6Mpa |
Max Working Pressure: |
5.3Mpa/8.0Mpa |
vessels of clean agent fire extinguishing systems, designed to safely store Novec1230 extinguishing agent. Manufactured from high-strength steel, these cylinders comply with NFPA 2001 and ISO 14520 international standards while also supporting alignment with Indonesian National Standards (SNI). They provide reliable agent storage solutions for data centers, telecommunications facilities, banks, hospitals, and industrial control rooms across Indonesia.
| Adaptation Aspect | Details |
|---|---|
| International & Local Standards Compliance | Systems comply with NFPA 2001 and ISO 14520, with design and installation capable of meeting SNI requirements |
| Environmental Compliance | Zero ODP, GWP < 1, and atmospheric lifetime of only 5 days, meeting Indonesia's green building and ESG commitments |
| HFC Phase-Down Resilience | As a Kigali Amendment signatory, Indonesia faces HFC phase-down pressures; Novec1230 is not subject to such restrictions, offering a long-term reliable solution |
| Highest Personnel Safety Margin | NOAEL of 10%, the highest among all clean agents, suitable for occupied spaces |
| Local Service Support | Licensed fire engineering companies in Jakarta (e.g., PT Totalfire Indonesia) provide Novec1230 system design, installation, and maintenance services |
Novec1230 cylinders are widely installed in the following Indonesian commercial and industrial facilities:
| Application | Typical Scenarios |
|---|---|
| Data Centers & Server Rooms | Data centers and enterprise server rooms in Jakarta, Surabaya, Bandung |
| Telecommunications Facilities | BTS sites, switching centers, communication hubs |
| Banks & Financial Institutions | Bank data centers, trading system rooms, vaults |
| Healthcare Facilities | Operating theaters, MRI rooms, pharmaceutical cold storage in major hospitals |
| Museums & Cultural Heritage | Archive storage, museums, cultural heritage preservation sites |
| Industrial Control Rooms & Electrical Rooms | Control rooms and electrical rooms in manufacturing, petrochemical, and power generation facilities |
| Commercial High-Rise Buildings | Electrical rooms and UPS rooms in malls, hotels, office towers |
| Oil & Gas Facilities | Refinery control rooms, offshore platform control rooms |
| Marine Vessels | Ship engine rooms and cargo holds |
Regulatory Note: Indonesian regulations require that generators, power distribution rooms, gas turbines, and other electrical installations in factories and commercial buildings be equipped with automatic fire suppression systems connected to automatic alarm systems. Clean agent gaseous systems, including Novec1230, are among the approved solutions.
High-Strength Steel Construction
Forged from high-quality carbon steel, available in both 25bar and 42bar working pressures, with maximum working pressures of 35bar and 60bar respectively
Various Capacity Options
Available in 40L, 70L, 90L, 100L, 120L, 150L, and 180L to accommodate different system design requirements
Long-Term Reliability
Following 3M's production exit, other approved FK-5-1-12 manufacturers offer equivalent agent quality and refilling services, allowing existing systems to continue operating without replacement
Safe & Reliable
Each cylinder undergoes rigorous hydrostatic pressure testing and air-tightness inspection, fitted with rupture discs and pressure gauges for long-term storage safety
Refillable Design
After agent discharge, cylinders can be returned to authorized refilling stations. Licensed fire engineering companies in Indonesia provide refilling and maintenance services
| Parameter | 25bar (4.2MPa) System | 42bar (5.6MPa) System |
|---|---|---|
| Filling Pressure (20°C) | 25bar | 42bar |
| Max Working Pressure (50°C) | 35bar | 60bar |
| Filling Density | ≤0.95kg/L | ≤1.08kg/L |
| Operating Temperature | 0~50°C | 0~50°C |
| Relative Humidity | ≤97% | ≤97% |
| Material | High Quality Carbon Steel | High Quality Carbon Steel |
| Applicable Standards | NFPA 2001, ISO 14520 | NFPA 2001, ISO 14520 |
System design can reference NFPA 2001 and ISO 14520 standards with alignment to SNI requirements
Cylinders can be integrated with NFPA 72 fire alarm systems
Assistance in coordinating with Indonesian licensed fire engineering companies (e.g., PT Totalfire Indonesia) for installation and commissioning
Technical documentation support including system design drawings and commissioning guides
For existing Novec1230 systems, post-3M exit guidance includes: cylinder condition assessment, valve support evaluation, spare part availability review, and contingency plan development for refilling