logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. Company Profile
products
Home > products > FK 5112 Fire Suppression System > FK 5112 Fire Suppression System Wide Application Class A B C Electrical Fires 100L Cylinder

FK 5112 Fire Suppression System Wide Application Class A B C Electrical Fires 100L Cylinder

Product Details

Place of Origin: Guangdong, China

Brand Name: Xingjin

Certification: CAL, CMA, CNAS, ILAC-MRA, CCC

Model Number: QMP100/4.2-FK

Payment & Shipping Terms

Minimum Order Quantity: 2 sets

Price: USD 2,200 - 3,100 / Set

Packaging Details: Plywood case with bubble bag and moisture barrier film, nozzles packed separately

Delivery Time: 15-20 working days after deposit or L/C receipt

Payment Terms: T/T,L/C,Western Union

Supply Ability: 400 sets per Month

Get Best Price
Product Details
Highlight:

Class A B C Electrical Fires

,

Wide Application Clean Agent

,

FK 5112 Multi Hazard Protection

Agent:
FK-5-1-12 / Novec 1230 / C6F12O
Cylinder Volume:
100L (40L-180L Optional)
Working Pressure:
4.2 MPa At 20 C (5.6 MPa Optional)
Filling Density:
1080 Kg/m3 Or Less
Fire Classes:
Class A, Class B, Class C, Electrical
Discharge Time:
10 Seconds Or Less
Protected Volume:
Up To 3600 M3
Actuation Modes:
Automatic, Electrical Manual, Mechanical Emergency Manual
Ozone Depletion Potential:
Zero
Working Temperature:
-10 C To +50 C
Agent:
FK-5-1-12 / Novec 1230 / C6F12O
Cylinder Volume:
100L (40L-180L Optional)
Working Pressure:
4.2 MPa At 20 C (5.6 MPa Optional)
Filling Density:
1080 Kg/m3 Or Less
Fire Classes:
Class A, Class B, Class C, Electrical
Discharge Time:
10 Seconds Or Less
Protected Volume:
Up To 3600 M3
Actuation Modes:
Automatic, Electrical Manual, Mechanical Emergency Manual
Ozone Depletion Potential:
Zero
Working Temperature:
-10 C To +50 C
Product Description

Wide Application FK 5112 Fire Suppression System – Class A, B, C and Electrical Fires

FK-5-1-12 (Novec 1230) is a fluoroketone clean agent that extinguishes by rapid heat absorption rather than by smothering or cooling with water. That mechanism works on solid, liquid, gas and energised electrical hazards alike, so one system specification covers sites that would otherwise need two or three different extinguishing technologies.

FK 5112 Fire Suppression System Wide Application Class A B C Electrical Fires 100L CylinderFK 5112 Fire Suppression System Wide Application Class A B C Electrical Fires 100L Cylinder

Fire Classes Covered

Class Hazard Typical site
Class A Solid combustibles such as paper, wood, textiles, cable insulation Archives, libraries, storage rooms, cable voids
Class B Flammable liquids, solvents, oils, paints Paint stores, solvent rooms, generator fuel areas
Class C Flammable gases Gas cylinder rooms, process gas cabinets
Electrical Energised equipment, electronics, switchgear Data centres, control rooms, transformer and battery rooms

Why One Agent Fits So Many Rooms

  • Discharges as a gas and behaves as a total flooding agent, reaching cable voids, raised floors and ceiling plenums.
  • Electrically non-conductive, so it can be used on live equipment without isolation.
  • Leaves no residue and no oily film, so rooms return to service after ventilation.
  • Zero ozone depletion potential and a short atmospheric lifetime of a few days.
  • Stored at moderate pressure, so the same cylinder hardware serves small and large rooms by changing volume and nozzle layout.

Technical Specifications

Parameter Specification
Agent FK-5-1-12 / Novec 1230 / C6F12O
Cylinder volume 100L (40L, 70L, 90L, 120L, 150L, 180L available)
Working pressure 4.2 MPa at 20 °C (5.6 MPa optional)
Filling density ≤1080 kg/m³
Discharge time ≤10 seconds
Protected volume Up to 3600 m³
Actuation Automatic, electrical manual, mechanical emergency manual
Power supply DC 24V / 1.6A
Ozone depletion potential Zero
Working temperature -10 °C to +50 °C
Certification CAL, CMA, CNAS, ILAC-MRA, CCC

Application Matrix

  • Data centres, server rooms and telecommunication hubs
  • Electrical switchgear, UPS and battery rooms
  • Archives, libraries and museum storage
  • Laboratories, chemical and solvent stores
  • Control rooms, instrumentation cabinets and clean rooms
  • Small marine engine rooms and offshore equipment enclosures

Scope of Supply

Seamless steel cylinder with FK-5-1-12 charge, cylinder valve, flexible discharge hose, pipe network and nozzles, control panel, smoke and heat detectors, sounder and strobe, warning plate and installation manual. Agent quantity is calculated per room volume, leakage and design concentration; volume and nozzle layout can be configured to the drawing.