logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. company profile
Products
Home > Products > FK-5-1-12 Clean Agents > FM200 Fire Extinguishing Agent (HFC-227ea) - 99.9% Purity Clean Agent for Data Centers with No Residue

FM200 Fire Extinguishing Agent (HFC-227ea) - 99.9% Purity Clean Agent for Data Centers with No Residue

Product Details

Place of Origin: Guangzhou,China

Brand Name: XINGJIN

Certification: CCC,CAC,ROHS

Model Number: XJ-QEO-006

Payment & Shipping Terms

Minimum Order Quantity: 1 set system

Price: Pricing based on quantity

Packaging Details: Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper

Delivery Time: According to product quantity

Payment Terms: T/T,L/C

Supply Ability: 30000set/month

Get Best Price
Product Details
Highlight:

99.9% Purity FM200 Fire Extinguishing Agent

,

Data Center Use HFC-227ea

,

No Residue FK-5-1-12 Clean Agents

Molecular Mass:
316.04
Filling Density:
≤ 1420 Kg/m³
Filling Accuracy:
±0.5%
Spraying Time:
≤10s
Cas:
756-13-8
Drug Output Pressure:
0~3.6 MPa
Molecular Mass:
316.04
Filling Density:
≤ 1420 Kg/m³
Filling Accuracy:
±0.5%
Spraying Time:
≤10s
Cas:
756-13-8
Drug Output Pressure:
0~3.6 MPa
Product Description

Heptafluoropropane filling agent


Product Overview:

    FM200 Fire Extinguishing Agent (HFC-227ea) is a clean, colorless, and electrically non-conductive gas used in modern fire suppression systems. With a minimum 99.9% GC purity, low moisture content (≤10 ppm), and zero ozone depletion potential (ODP 0), FM200 is an environmentally friendly alternative to traditional fire agents such as CO₂ and Halon.

This clean agent vaporizes completely after discharge and leaves no residue, making it ideal for protecting sensitive equipment and valuable assets. FM200 does not corrode metals or electronic components and produces no secondary pollution, ensuring minimal downtime after fire suppression.

FM200 Fire Extinguishing Agent (HFC-227ea) - 99.9% Purity Clean Agent for Data Centers with No Residue 0

Technical Parameter:

Project Parameter
Suitable Extinguishing Media FM200(HFC-227ea),Nitrogen
Maximum Filling Pressure 5.6 MPa
Nitrogen Pressure Reduction Range 0~ 10 MPa adjustable (commonly used: 2.5 MPa, 4.2 MPa, 5.6 MPa)
Drug Output Pressure 0~3.6 MPa
Vacuum Degree ≤ -0.09 MPa
Filling Pressure Alarm 0~ 10 MPa (Adjustable to set value, alarm warning light on)
Filling Density ≤ 950 kg/m³
Filling Accuracy ±0.5%
Ambient Temperature 0~50℃
Power Requirements AC 220V ,50Hz
Equipment Size 720×800×1280 mm (Excluding the wheel)
External Connection Thread Drug inlet and outlet threads and nitrogen interface: M22 × 1.5
Other Reserved weight alarm indicator interface (requires external intelligent electronic weighing device)

FM200 Fire Extinguishing Agent (HFC-227ea) - 99.9% Purity Clean Agent for Data Centers with No Residue 1

Wide Range of Applications:

FM200 is suitable for total flooding fire suppression systems and can extinguish Class A, B, and electrical fires quickly and effectively. It is widely used in:

  • Data centers and server rooms
  • Computer rooms and telecom facilities
  • Electrical and control rooms
  • Generator and transformer rooms
  • Archives, libraries, and museums
  • Financial institutions and government facilities
  • Chemical warehouses and oil depots

Key Advantages & Benefits:

  1. Clean agent with no residue after discharge
  2. Fast fire suppression with minimal asset damage
  3. Non-corrosive and safe for sensitive electronics
  4. Electrically insulated gas for electrical fire protection
  5. Environment-friendly with zero ODP
  6. Efficient total flooding capability
  7. Reduces system downtime and maintenance costs



 Equipment valve body function:

F1 pressure reducing valve Control the pressure of nitrogen entering the system to ensure stable and safe filling process.
F2 pressure relief valve

Release excess pressure in emergency situations to protect equipment and gas

cylinders from high pressure damage.

F3 Pharmaceutical Storage Valve Control the pipeline for the flow of fire extinguishing agent from the storage tank to the filling cylinder.




F4 nitrogen storage valve Control the entry of nitrogen from the storage tank into the equipment pipeline to provide pressure for the filling of fire extinguishing agents.
F5 gas cylinder valve

Used to connect fire extinguishing agent cylinders and control the opening or closing

of cylinder fluid pipelines.

F6 vacuum valve Used to open or close the air inside the extracted gas cylinder, reduce the pressure inside the cylinder, and ensure the purity of the fire extinguishing agent filling.


Applicable places:
  Heptafluoropropane fire extinguishing agent has a good protective effect on precision equipment and precious property
It is mainly applicable to fire protection in places or equipment such as computer rooms, communication rooms, control rooms, rooms for valuable equipment, storage rooms for cultural relics and materials, libraries and archives, data storage rooms, generator rooms, oil-immersed transformer rooms, substation rooms, circuit breakers, circulating equipment and hydraulic equipment, drying equipment, dust removal equipment, and spray painting production lines

Precautions:
At present, there is no standardized service life for heptafluoropropane gas. However, we still need to do a good job in the daily maintenance and upkeep of the gas fire extinguishing system. We suggest that the company train personnel to be professionally responsible for this project, and conduct daily appearance and pressure gauge reading checks on the entire system to see if there are any abnormal phenomena. The inspection work should be carried out on a weekly, monthly or annual basis. Every five years, contact the manufacturer to conduct a water pressure strength test on the storage bottles at a pressure of 5.3MPa. Only after passing the test can they be used again. If there is corrosion, damage or any doubt about their safety and reliability, replace them in a timely manner. Under normal circumstances, heptafluoropropane gas cylinders should be replaced every 10 years, and gas cylinders every 5 years.

FAQ:
Q: Are you a trading company or a manufacturer?
A: We are both a manufacturer and a trading company. We have owned our own factory for nearly 15 years and are committed to providing high-quality service to our overseas customers.

Q: Can you do OEM production?
A: We accept all OEM orders. Simply contact us with your design proposal, and we will provide you with a reasonable price as soon as possible.

Q: How do you ensure product quality?
A: We have TUV/SGS/ISO quality control systems and strictly adhere to them. We have a professional quality inspection team, and each packer conducts a final inspection according to the quality inspection instructions before packaging.

Q: What is the delivery time?
A: Depending on the minimum order quantity, we ship within 10-15 business days after receiving the deposit. 20-foot container orders typically take 30-35 days to fulfill.
Q: Besides filling machines, do you offer other conventional firefighting equipment?
A: Of course. We offer a full range of professional firefighting equipment, from sound and light alarms to smoke exhaust valves, as well as FM200, CO2, and Novec1230 fire suppression systems. Feel free to contact us!
Please inquire about the specific delivery time based on your order quantity.

Why choose us?​
FM200 Fire Extinguishing Agent (HFC-227ea) - 99.9% Purity Clean Agent for Data Centers with No Residue 2