Product Details
Place of Origin: Guangzhou,China
Brand Name: XINGJIN
Certification: CCC,GB 50116-2013
Model Number: JTF-GOM-JBF5000C
Payment & Shipping Terms
Minimum Order Quantity: 100 set system
Price: USD3-4/pc
Packaging Details: Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper
Delivery Time: 15-20days
Payment Terms: T/T,L/C
Supply Ability: 300000 sets per month
Alarm Concentration: |
0.65~15.5%FT |
Light Intensity: |
135cd |
Nominal Working Pressure: |
8Mpa |
Power: |
90 To 270VAC, 50Hz/60Hz |
Working Ambient: |
-10℃~50℃ |
Operating Pressure: |
0.06±0.01MPa |
Alarm Output: |
Audible And Visual |
Working Temperature: |
-10℃~50℃ |
Alarm Concentration: |
0.65~15.5%FT |
Light Intensity: |
135cd |
Nominal Working Pressure: |
8Mpa |
Power: |
90 To 270VAC, 50Hz/60Hz |
Working Ambient: |
-10℃~50℃ |
Operating Pressure: |
0.06±0.01MPa |
Alarm Output: |
Audible And Visual |
Working Temperature: |
-10℃~50℃ |
This point-type multisensor smoke and heat detector is an intelligent fire alarm detector designed for commercial buildings, integrating smoke detection and temperature detection into one unit. Built with a dedicated microprocessor, it simultaneously monitors environmental smoke concentration and temperature changes. When smoke concentration reaches the alarm threshold or temperature meets the set conditions, the detector immediately uploads alarm information to the fire alarm control panel, achieving rapid and reliable fire warning. The product adopts non-polarized two-bus technology, supports long-distance communication, and can seamlessly connect with XINGJIN Fire series controllers, providing comprehensive fire detection protection for various commercial premises.![]()
This detector is widely used in the following commercial and public buildings:
Commercial Complexes: Shopping malls, department stores, brand specialty stores, supermarkets
Office Buildings: Office towers, business centers, industrial park offices, co-working spaces
Public Facilities: Hospitals, schools, libraries, cinemas, exhibition halls, museums
Transportation Hubs: Airport terminals, railway stations, subway stations, passenger transport centers
Hotels & Restaurants: Star-rated hotels, business hotels, restaurants, banquet halls
Educational & Cultural Places: Teaching buildings, laboratories, conference rooms, lecture halls
| Parameter | Value |
|---|---|
| Operating Temperature | -10~+50℃ |
| Storage Temperature | -20~+65℃ |
| Relative Humidity | ≤95% (No condensation) |
| Parameter | Value |
|---|---|
| Explosion-Proof Mark | Not applicable |
| Parameter | Value |
|---|---|
| Operating Voltage | 11 Protocol: Bus DC24V (DC18V~28V) modulated, provided by controller 62 Protocol: Bus DC24V (DC13V~28V) modulated, provided by controller |
| RF Electromagnetic Field Immunity | 30V/m |
| Monitoring Current | ≤ 150μA (DC24V) |
| Starting Current | ≤ 400μA (DC24V) |
| Indicator Light | Normal monitoring status: Red flashing LED Alarm status: Red constant LED |
| Parameter | Value |
|---|---|
| Wiring System | Non-polarity two-wire bus |
| Addressing Range | 11S Protocol: 1~200 62 Protocol: 1~252 |
| Addressing Method | Encoder addressing |
| Max Transmission Distance | 1000m (Conductor cross-section ≥1.0mm²) |
| Parameter | Value |
|---|---|
| Compatible Controllers | JBF-11SF, JBF-11SF-C, JBF50XX, JBF51S series, etc. |
| Parameter | Value |
|---|---|
| Appearance Color | PANTONE Warm Gray 1C |
| Housing Material | Plastic |
| Product Weight | 96g |
| Dimensions | Φ100mm × H53mm (including base) |
| Parameter | Value |
|---|---|
| Protection Area | 20-30m² |
| Thermal Classification | A2R (factory default), BS |
The detector integrates dual functions of smoke detection and temperature detection. It is equipped with a dedicated fire detection microprocessor and combines advanced fire detection intelligent algorithms. It can simultaneously identify changes in smoke concentration and environmental temperature. When the smoke concentration reaches the alarm threshold or the temperature meets the requirements of A2R or BS categories, it will immediately upload the alarm information. The dual verification mechanism effectively distinguishes between real fires and environmental disturbances, minimizing false alarms and avoiding personnel evacuations and business interruptions caused by false alarms in commercial premises.
Adopting non-polarized two-bus technology, the standby current is as low as 150μA, and the alarm current does not exceed 400μA, achieving extremely low power consumption. The communication distance can reach up to 1000 meters, supporting coverage of large commercial buildings. The non-polarized bus design eliminates the need for polarity distinction during wiring, significantly reducing installation difficulty and labor costs. It supports addressing ranges of 1-200 points for 11 protocol or 1-252 points for 62 protocol, meeting the requirements of medium to large commercial projects.
The radio frequency electromagnetic field immunity reaches 30V/m, far exceeding industry standards, ensuring stable operation in complex electromagnetic environments found in shopping malls (such as wireless signals, intercom systems, and electronic equipment interference). The hardware circuit is highly integrated using SMT surface mount technology, ensuring stable and reliable performance. It features temperature sensor abnormality alarm function, timely detecting equipment faults to ensure the system always operates normally.
Supports on-site addressing with electronic programmers, with flexible addressing ranges, facilitating engineering commissioning and later maintenance. The plug-in structure design makes installation and removal simple and convenient. The detector can be easily removed for cleaning or replacement without rewiring. The indicator light flashes red in normal monitoring status and stays red in alarm status, providing clear status indication for easy daily inspection.
The product is strictly designed and manufactured according to national standards, complying with GB 4715-2005, GB 4716-2005, and Q/JBF001-2019 requirements. It has passed the inspection of the National Center for Quality Supervision and Testing of Fire Electronic Products, ensuring reliable quality and trustworthiness.
| Parameter | Specification |
|---|---|
| Operating Voltage | Bus DC24V (DC18V~28V) modulated, provided by controller |
| Standby Current | ≤150μA (DC24V) |
| Alarm Current | ≤400μA (DC24V) |
| Indicator Light | Standby: Flashing red; Alarm: Steady red |
| Wiring Method | Non-polarized two-bus |
| Addressing Range | 11 protocol: 1-200; 62 protocol: 1-252 |
| Addressing Method | Electronic programmer |
| Max Transmission Distance | 1000m (conductor cross-section ≥1.0mm²) |
| Operating Temperature | -10℃ to +50℃ |
| Storage Temperature | -20℃ to +65℃ |
| Relative Humidity | ≤95% (non-condensing) |
| RF Immunity | 30V/m |
| Heat Sensitivity Class | A2R (default), BS |
| Protection Area | 20-30m² |
| Dimensions | Φ100mm × H53mm (including base) |
| Weight | 96g |
| Housing Material | Plastic, off-white |
Reduce Operational Risks: Accurate dual-detection technology effectively identifies real fires, reducing false alarm rates and avoiding unnecessary evacuation and business losses in commercial premises, ensuring normal business operations.
Enhance Safety Levels: Simultaneously monitoring smoke and temperature changes provides good response to both smoldering and open fires, offering more comprehensive fire protection for commercial buildings and safeguarding personnel and property.
Save Construction Costs: Non-polarized two-bus design simplifies wiring processes, saving cable and labor costs; long-distance communication capability reduces the need for relay equipment, lowering overall system costs.
Simplify Maintenance: On-site address modification with electronic programmers, plug-in structure for easy replacement, and intuitive indicator light status significantly reduce the workload of property maintenance teams.
Wiring Requirements: Use flame-retardant twisted pair with conductor cross-section ≥1.0mm² (ZR-RVS 2×1.0mm²). Connect L1 and L2 to base terminals L1 and L2 respectively, no polarity distinction required.
Installation Steps: Secure the base to the pre-embedded box with two M4 screws; write the address using a programmer; insert the detector into the base and tighten clockwise.
Dust Protection: Do not remove the dust cover before the detector is put into use to avoid dust contamination affecting performance.
Commissioning Method: After installation, operate the controller for registration; use a specialized temperature gun to heat the grid holes or perform smoke testing; the indicator light stays on when the detector alarms; reset the controller to return to normal monitoring.
Regular Maintenance: It is recommended to conduct alarm tests every six months; according to GB29837-2013, the product service life generally does not exceed 12 years.
During use, installation and operation must strictly follow the requirements of this manual
The detector should not be installed in places with high wind speed, excessive oil smoke, or frequent steam
The company reserves the right of final interpretation of this manual without prior notice