Home > products > FM200 Fire Suppression System > FM200 Fire Suppression System with ≤10s Discharge Time, 4.2MPa Working Pressure for Single-Zone Protection

FM200 Fire Suppression System with ≤10s Discharge Time, 4.2MPa Working Pressure for Single-Zone Protection

Product Details

Place of Origin: Guangzhou,China

Brand Name: XINGJIN

Certification: GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1

Model Number: GQQ40 GQQ70 GQQ90 GQQ100 GQQ120 GQQ150 GQQ180

Payment & Shipping Terms

Minimum Order Quantity: 5 set

Price: USD420-598/set

Packaging Details: Wooden Box Or Plywood Outer Box With Bubble Bag Or Paper

Delivery Time: 15-20days

Payment Terms: T/T,L/C

Supply Ability: 3000set/month

Get Best Price
Product Details
Highlight:

≤10s Discharge Time FM200 Fire Suppression System

,

4.2MPa Working Pressure FM200 Fire Suppression System

,

Single-Zone Protection FM200 Fire Suppression System

Filling Pressure:
2.5Mpa
Max Working Pressure:
4.2Mpa
Relief Pressure:
5.0±0.225Mpa
Power:
DC24V/1.6A
Spraying Time:
≤10s
Working Temperature:
0~50℃
Filling Pressure:
2.5Mpa
Max Working Pressure:
4.2Mpa
Relief Pressure:
5.0±0.225Mpa
Power:
DC24V/1.6A
Spraying Time:
≤10s
Working Temperature:
0~50℃
Product Description
Single Zone Single Bottle FM200 Cabinet Pipe System
Reliable Gas Fire Equipment for Industrial Use
Product Overview
The FM200 Single-Zone Single-Cylinder Pipe Network Fire Suppression System is an automatic gas fire extinguishing system using HFC-227ea (FM200) as the extinguishing medium, specifically designed to protect a single protected enclosure. The system consists of one set of storage equipment protecting one fire zone, making it suitable for independent single protection areas with special requirements.
The system operates at 4.2MPa or 5.6MPa storage pressure, with single-cylinder agent capacities ranging from 40kg to 180kg. The discharge time is ≤10 seconds, enabling rapid fire suppression at the early stage. The system supports three activation modes: automatic, electrical manual, and mechanical emergency manual, ensuring reliable operation under any condition.
Technical Specifications
Parameter 4.2MPa System 5.6MPa System
Storage Pressure (20 °C) 4.2 MPa 5.6 MPa
Max. Working Pressure (50 °C) 5.3 MPa 8.0 MPa
Extinguishing Agent HFC-227ea (FM200) HFC-227ea (FM200)
Filling Density ≤950 kg/m³ ≤1080 kg/m³
Cylinder Capacities 40L / 70L / 100L / 120L / 150L / 180L 70L / 90L / 120L
Discharge Time ≤10 seconds ≤10 seconds
Actuation Power DC24V / 1.5A DC24V / 1.5A
Driving Nitrogen Pressure (20 °C) 6.0 ± 1.0 MPa 6.0 ± 1.0 MPa
Max. Protection Area (Single Zone) 800 m² 800 m²
Max. Protection Volume (Single Zone) 3,600 m³ 3,600 m³
Operating Temperature Range 0°C to +50°C 0°C to +50°C
Cylinder Room Temperature -10°C to +50°C -10°C to +50°C
Compliance Standard GB25972-2010 GB25972-2010
System Components
The FM200 single-zone single-cylinder pipe network system consists of three main parts:
1. Fire Extinguishing Equipment
Component Description
Agent Storage Cylinder Stores FM200 agent; welded steel cylinder with red epoxy coating
Container Valve Controls agent release; supports pneumatic and manual operation
Siphon Tube Ensures complete agent discharge from the cylinder
Flexible Hose Connects container valve to the manifold
Liquid Check Valve Prevents agent backflow from manifold to cylinder
Manifold Collects agent from multiple cylinders
Safety Relief Valve Automatic overpressure protection
Discharge Nozzle Distributes agent evenly into the protected area
2. Pipe Network
  • High-pressure galvanised steel pipes
  • Flanges, elbows, tees, reducers
  • Transports agent from cylinder room to protected area
3. Electrical Controls
  • Fire detectors and gas fire control panel
  • Audible and visual alarms, alarm bells
  • Manual start/stop buttons
  • Discharge indicator lights
  • Signal feedback device
Working Principle
The system uses total flooding fire suppression. The working principle is as follows:
Step 1: Fire Detection
  • Smoke detectors and fixed-temperature heat detectors continuously monitor the protected area
  • When a single detector sends a fire signal, the control panel activates audible/visual alarms without starting the extinguishing system
Step 2: Double Confirmation
  • When both detectors simultaneously send fire signals, the system enters a delay state
  • Indoor and outdoor alarms are activated, and linked equipment (dampers, HVAC) is closed
Step 3: Personnel Evacuation (Delay Phase)
  • Delay time is adjustable from 0 to 30 seconds
  • Personnel can safely evacuate during this period
  • "Emergency Stop" button can cancel activation during the delay
Step 4: Agent Discharge
  • After the delay, the control panel outputs DC24V to activate the solenoid valve
  • The solenoid valve releases high-pressure nitrogen from the drive cylinder
  • Nitrogen opens the container valves on the agent cylinders via the start-up pipeline
  • Agent flows through flexible hoses, manifold, and pipe network to the nozzles
Step 5: Total Flooding Fire Suppression
  • Agent fills the entire protected area within 10 seconds
  • Extinguishing concentration (8%~10%) is rapidly established
  • Fire is suppressed effectively
About FM200 Extinguishing Agent
FM200 (HFC-227ea) is a clean agent that extinguishes fire primarily through chemical inhibition, supplemented by physical cooling effects.
Key Properties:
  • Colourless, odourless, low toxicity, non-conductive
  • Does not contaminate protected objects; no damage to precision equipment
  • Low extinguishing concentration; reliable suppression of Class B, C, and electrical fires
  • Compact storage; high critical temperature; liquefied storage at room temperature
Environmental Properties:
  • Zero Ozone Depletion Potential (ODP) - no damage to the ozone layer
  • Atmospheric lifetime of approximately 31~42 years; superior to halogenated agents
  • NOAEL value of 9% - safe for occupied spaces
Applications
The FM200 single-zone single-cylinder system is suitable for a wide range of protected enclosures:
Industry / Sector Typical Applications
Data Centres & IT Computer rooms, data processing centres
Telecommunications Switch rooms, telecom centres, signalling transfer points
Power Facilities Power distribution rooms, generator rooms, relay rooms, transformer rooms
Cultural Heritage Libraries, archives, museums, valuable item storage
Medical Facilities Expensive medical equipment rooms, precision instrument rooms
Industrial Facilities Clean rooms, control rooms, flammable liquid storage areas
Marine Ship engine rooms, cargo holds
Suitable Fire Types:
  • Class A: Solid surface fires (paper, wood, textiles)
  • Class B: Liquid fires or meltable solid fires
  • Class C: Electrical fires (energised equipment)
Not Suitable For:
  • Chemical products containing oxidising agents (e.g., nitrocellulose, gunpowder)
  • Reactive metals (potassium, sodium, magnesium, titanium, etc.)
  • Metal hydrides (potassium hydride, sodium hydride, etc.)
  • Self-decomposing substances (hydrogen peroxide, hydrazine, etc.)
Key Advantages
1. Dedicated Single-Zone Protection
Designed specifically for single protected areas with precise agent quantity calculation - no agent waste and simple system configuration.
2. Fast Response - Effective Fire Suppression
Discharge time ≤10 seconds, rapidly establishing extinguishing concentration at the early fire stage to control fire spread and minimise damage.
3. Multiple Activation Methods - Reliable Operation
Automatic: Dual-detector confirmation triggers automatic agent release
Electrical Manual: Emergency push button manual activation
Mechanical Emergency: Direct manual operation of container valves
4. Clean Agent - No Secondary Damage
FM200 is non-conductive, non-corrosive, and leaves no residue. No post-discharge cleanup is required, enabling rapid business recovery.
5. Total Flooding - No Blind Spots
The pipe network and nozzles distribute agent evenly throughout the protected area, ensuring complete coverage with no protection gaps.
Activation Modes Detail
Automatic Mode
With control selector in the "Automatic" position:
  • Single detector alarm: audible/visual alarm only - no activation
  • Dual detectors alarm: 30-second delay → linked equipment shutdown → agent release
  • "Emergency Stop" can cancel activation during the delay
Electrical Manual Mode
With control selector in the "Manual" position:
  • Detector alarm triggers audible/visual alarm only - no activation
  • Personnel confirm fire, then press "Emergency Start" to activate
  • Alarm signal continues until reset
Mechanical Emergency Mode
For situations where the control panel is completely inoperative:
  1. Manually close linked equipment and cut power
  2. Open the selector valve (if present)
  3. Manually open container valves one by one or in groups to release agent
Installation Instructions
Cylinder Room Requirements
  • Temperature: -10°C to +50°C
  • Relative humidity: ≤97%
  • Keep dry and well-ventilated; avoid direct sunlight
  • No flammable, explosive, or corrosive substances
  • Dedicated, independent room with easy access
Cylinder Installation Requirements
  • Arranged according to design documents with height difference ≤20mm
  • Clearance of ≥1.0m between operating surfaces and walls
  • Cylinders must be installed vertically with secure brackets
  • Labels should face front; pressure gauges should be easily visible
Manual Emergency Operation
To manually open container valves:
  1. Remove the safety pin from the actuator
  2. Engage the handle and rotate the cam lever
  3. Open all container valves one by one to release agent
Maintenance and Servicing
Routine Maintenance
  • Monthly: Visual inspection - no impact deformation, no rust, coating intact, safety pins and seals in place
  • Annually: Check storage pressure; if gauge is not in the green zone, weigh the cylinder to verify agent quantity
  • Every 5 Years: Full system inspection - disassemble, clean, reassemble, and re-test all components
Post-Discharge Restoration
After the system has been discharged, a qualified service provider must perform:
  1. Replace the solenoid actuator sealing diaphragm
  2. Re-fill the agent cylinders according to design requirements
  3. Re-charge the driving nitrogen to the specified pressure
  4. Perform full system re-commissioning before returning to service
Safety Precautions
⚠️ Agent cylinders contain high-pressure gas - only qualified personnel should handle them
⚠️ System discharge produces hydrogen fluoride gas - ensure evacuation before activation
⚠️ Maintain required soaking time after discharge; do not enter without ventilation
⚠️ Wear breathing apparatus if entry is necessary before ventilation
Packaging and Shipping
Packaging:
  • Plywood outer boxes with bubble bags or paper cushioning
  • All components individually secured to prevent transit damage
  • Product certificate, instruction manual, and installation drawings included
Shipping Precautions:
  • Avoid rough handling and inversion during transport
  • Storage temperature: -10°C to +50°C
  • Protect from rain and damp conditions
  • Store away from heat sources and open flames
Frequently Asked Questions
Q: What is the difference between single-zone and combined distribution systems?
A: A single-zone system uses one set of storage equipment to protect one protected area. A combined distribution system uses one set of storage equipment to protect multiple areas via selector valves, with agent quantity calculated based on the largest protected zone (maximum 8 zones per system).
Q: What is the maximum protection range of a single zone?
A: Maximum protection area is 800m², and maximum protection volume is 3,600m³ per zone.
Q: What is the agent discharge time?
A: Discharge time is ≤10 seconds, ensuring rapid extinguishing concentration build-up at the early stage of a fire.
Q: What power supply is required for the system?
A: The solenoid valve requires DC24V/1.5A. The control panel requires AC220V main power with DC24V backup power.
Q: How can I check for agent leakage?
A: The pressure gauge provides an initial indication - the reading should be in the green zone. Annual weighing provides accurate leakage data. If leakage exceeds 5% of the filling quantity, refill or replace.
Why Choose Guangzhou Xingjin Fire Equipment?
  • 15+ Years Manufacturing Experience: Professional fire equipment manufacturer with competitive pricing and stable supply
  • Quality Assurance: Products manufactured in compliance with GB25972-2010 and other national standards
  • Export Experience: Products exported to the Middle East, Southeast Asia, and other global markets
  • Technical Support: Comprehensive support from system selection to installation
  • After-Sales Service: 24-hour response, 72-hour repair service