Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582
Product Details
Place of Origin: China
Brand Name: xingjin
Certification: GSG\TUV\ I S O 9 0 0 1, 1 4 0 0 1, 4 5 0 0 1
Model Number: QYD5.3-XJ
Payment & Shipping Terms
Minimum Order Quantity: 2 set system
Price: negotiation
Packaging Details: Plywood outer box with bubble bag or paper
Delivery Time: 15-20 working days after payment or receipt of L/C
Payment Terms: T/T, L/C
Supply Ability: 30000 set system
Nominal Diameter: |
32mm |
Working Pressure: |
8Mpa |
Equivalent Length: |
2.63m |
Connection Thread: |
M45×2 |
Model: |
QYD5.3-XJ |
Opening Pressure: |
≤0.4MPa |
Nominal Diameter: |
32mm |
Working Pressure: |
8Mpa |
Equivalent Length: |
2.63m |
Connection Thread: |
M45×2 |
Model: |
QYD5.3-XJ |
Opening Pressure: |
≤0.4MPa |
Fire Safety Equipments Liquid Flow Check Valve Flow Regulating Valve
Liquid Flow Check Valve
Description:
Liquid flow check valve is fixed between high pressure hose and manifold.It's a kind of automatic valve used in duct system working based on the power of fluid medium itself. The main function of this valve is to stop the medium from back off and bleeding from the container. It's also suitable for using as the duct of assistance system for supplying when the pressure is higher than main system.
Fire Safety Equipments Liquid Flow Check Valve and Flow Regulating Valve are important components of fire sprinkler systems. These valves help to regulate the flow of water or other fire-retardant liquids through the system, ensuring that the system is operating efficiently and effectively.
Liquid Flow Check Valves are designed to allow the flow of liquid in one direction while preventing flow in the opposite direction. These valves are used to prevent backflow, which can contaminate the water supply with fire suppressant chemicals or other contaminants. They are typically installed in the pipe that leads from the water source to the sprinkler system and can be either spring-loaded or weighted to ensure proper function.
Flow Regulating Valves, on the other hand, are used to control the flow of liquid through the fire sprinkler system. They are designed to maintain a specific flow rate, regardless of changes in water pressure. This ensures that the sprinklers will receive the appropriate amount of water to extinguish a fire, even if the pressure in the system changes due to multiple sprinkler activations or other factors.
Both Liquid Flow Check Valves and Flow Regulating Valves are critical components of a fire sprinkler system. They help to ensure that the system is operating correctly and efficiently, reducing the risk of property damage and injury in the event of a fire. These valves are typically installed during the construction process of a building and are regularly inspected and tested to ensure they are functioning correctly.
Installation attention:
There is a mark like this “ ”on liquid flow check valve .It indicates the direction of fluid, it should not be reversed when installation, be sure that the direction of fluid is same with allow.
Company Introduction
Guangzhou Xingjin Fire Equipment Co., Ltd. is situated in Guangzhou, which is vital to connection between China and the rest of the globe. It is surrounded by excellent transportation and a lovely environment. We are a manufacturer, and our professional and experienced staff, which consists of the program design team, the skillful installation team, the quality detecting team, and the after-sell service team, is dedicated to the study and development of HFC-227ea (FM200) products. The FM200 fire suppression system, the cabinet type FM200 fire suppression system, the automated FM200 fire extinguisher (ceiling mounted style), the fire detecting tube suppression system, and the automatic fire suppression tube are all currently commonly utilized. As a result of high-quality products and services as well as the good reputation, our company is well-received by the customers in China.
Why Choose Us
• 5 years quality guarantee
• Xingjin is running in a high efficiency management system
• Advanced equipments & professional engineers to promise all products are quite satisfactory.
• We provide 8×6 hrs technical support and service.
After-Sale Service
• We have an efficient sales and after sales team to promise slove all client's question in time.
• We provide 8×6 hrs technical support and service.
FAQ
Q1: Are you a manufacturer or a trading company?
A1: We are a manufacturer.
Q2: Is OEM products available?
A2: Yes, we welcome your own design and drawing.
Q3: Where is your factory? Can I visit it?
A3: Our factory locates in Shilou, Panyu, Guangzhou, Guangdong, China.
Of course yes. We always welcome and wait for your visit.
Q4: How can I get to your factory?
A4: Because of the convenient transportation here, you can take a taxi or come here by subway. If you come here by subway, you need to take the line four and get off at Shiqi station. Then walk out the station for taking No. 126 bus and get off at Yuexi station.