Lastest company news about Application of Hang the FM200 fire extinguishing device 2024/05/24
Application of Hang the FM200 fire extinguishing device
Hang the FM200 fire extinguishing device 1. Product overview       The suspended FM200 automatic fire extinguishing device is a kind of gas fire extinguishing device without pipe network (also known as prefabricated fire extinguishing system), which is a fire extinguishing system with linkage control function and pre-designed and assembled complete sets of fire extinguishing agent storage device and spray assembly according to certain application conditions. The suspended SEvofluoropropane automatic fire extinguishing device is divided into two kinds: electromagnetic suspension and fixed temperature suspension.      The fixed temperature type hanging fire extinguishing device is composed of a fire extinguishing agent storage tank, a glass bubble nozzle and a pressure display component, which can be suspended or fixed on the wall, and has the characteristics of no occupation, no electrical connection and easy installation. A type of fire extinguishing device that can automatically spray extinguishing agent in case of fire. The valve design of the hanging gas fire extinguishing device has the advantages of large diameter, short discharge time and rapid fire extinguishing. Because there is no pipe network, the construction and installation is simple and the project investment is reduced. The same fire extinguishing device is installed above the protection area or on the surrounding walls, and does not occupy the ground space of the protection area. 2. Main performance and parameters       First, the fire extinguishing agent storage device and spray components and other parts are pre-designed and assembled in complete sets, which is conducive to the mass production of finished products and semi-finished products, shorten the production cycle and reduce the production cost.       Second, there is no need to set up a special gas cylinder room, the design, installation, use and maintenance is simple, suitable for places that are not suitable for installing pipeline systems, single protection areas, and places where multiple protection areas are far apart. In addition, when the project is renovated, the device is flexible, can benefit from old use, reduce the overall difficulty of construction, and save installation costs.        Third, the gas fire extinguishing device spray time is short, the fire extinguishing speed is fast, and the loss of the residual amount of the fire extinguishing agent in the pipeline is not generated. From the three characteristics of the above hanging fire extinguishing device, it is currently a semi-fixed fire extinguishing device in terms of improving fire extinguishing efficiency, saving costs, and installation and construction, which can be regarded as a more scientific fire extinguishing equipment in mobile fire extinguishing places. 3. How it works        When the temperature of the protected area rises to the temperature set by the thermomercuric meter, the mercury meter is damaged by thermal expansion and the valve is opened, and the extinguishing agent is sprayed from the nozzle. 4. Application scope        It can be used in power distribution room, transformer room, instrument equipment room, small oil depot, computer room, software library, communication room, archives and cultural relics reference room and other small protection areas.  
Read More
Lastest company news about FM200 fire extinguishing system introduce 2024/05/24
FM200 fire extinguishing system introduce
FM200 gas fire extinguishing system 1. Product overview        FM200 gas fire extinguishing system is composed of bottle group, fire extinguishing agent bottle group, container valve, metal hose, check valve (fire extinguishing agent pipeline), collector pipe, safety release device, selection valve, signal feedback device, fire extinguishing agent conveying pipeline, nozzle, drive gas bottle group, electromagnetic driving device, drive gas pipeline, check valve (drive gas pipeline), etc. According to the requirements of different application sites, it can be composed of unit independent system and combined distribution system, and adopt the full flood fire extinguishing method to achieve fire extinguishing protection for single and multi-protection areas, with advanced technology, high fire extinguishing efficiency and easy maintenance. Sevofluoropropane fire extinguishing equipment is divided into 4.2MPa and 5.6MPa, with automatic, manual and mechanical emergency operation three starting modes. 2. Main performance and parameters        First, the cylinder with pipe network system is independently set in the cylinder of the protection zone, and the pipeline can extend to the inside of the protection zone, and the gas is transported to the sprinkler through the pipe network, and the sprinkler is distributed according to the demand and specifications, and the spraying is average, and the fire extinguishing effect is good. Second, for protected areas with multiple partitions or multiple rooms, a pipe network system can protect multiple protected areas with the same set of systems. By selecting the valve control, the fire extinguishing of the agent can be carried out according to the fire area, avoiding the one-time spraying of the agent. Third, the gas fire extinguishing device spray time is short, the fire extinguishing speed is fast, and the loss of the residual amount of the fire extinguishing agent in the pipeline is not generated. From the three characteristics of the above pipe network fire extinguishing device, it is currently a semi-fixed fire extinguishing device in terms of improving fire extinguishing efficiency, saving costs, and installation and construction, and can be regarded as a more scientific fire extinguishing equipment in the mobile transformation of fire extinguishing places. 3. How it works (1) Unit independent system refers to a set of fire extinguishing agent storage device to protect a fire extinguishing system in a protected area, which is used in places with special requirements and independent protected areas. (2) Combined distribution system refers to the use of a set of fire extinguishing agent storage device through the pipe network selection distribution, to protect two or more protection areas. The distribution control is identical to the unit independent system except for the combination of a starting gas check valve and a selection valve. 4. System application scope       FM200 gas fire extinguishing system in the world has been widely used in power plants, communications, radio and television, petrochemical, railway and other systems, often used in books, archives, bills and cultural relics database protection area, oil-immersed transformer room, with oil switch distribution room and self-contained generator room protection area, communication room and computer room protection area.
Read More
Lastest company news about FM200 cabinet gas fire extinguishing device construction scheme 2024/05/23
FM200 cabinet gas fire extinguishing device construction scheme
Archives room FM200 gas fire extinguishing device construction scheme 1. System introduction      FM200 cabinet gas extinguishing device does not need to set up a special bottle storage room, the entire cabinet is set in the protection area, suitable for computer room, archives, valuables storage, communication room and other small space protection area, several cabinet devices can also be used together to protect the larger protection area. When a dedicated bottle storage room cannot be set up in the building, or although there is a storage room, the transmission distance is too far to meet the engineering design requirements, or it is inconvenient to install the system pipe network in the protection area.      FM200 gas fire extinguishing device has short injection time and fast fire extinguishing speed. The device can be equipped with single zone gas control panel for cabinet fire extinguishing system produced by our company. The starting mode is automatic control, manual electrical control and mechanical emergency manual control. Automatic control and manual electrical control can be switched. Under normal circumstances, manual control should be used, and it can be converted to automatic control in the case of no one in the protected area. When automatic control and manual electrical control cannot be performed, mechanical emergency manual control should be used. 2. System installation      The installation site of the cabinet fire extinguishing system shall meet the following requirements: (1) The ambient temperature is 0' ° C ~50 ° C, and it is dry and well-ventilated: (2) The air shall not contain explosive, conductive dust and harmful substances that corrode parts, otherwise it must be protected, and the device shall not be shaken and impacted; (3) The whole cabinet must be able to install smoothly, and tilt is not allowed; (4) The protection area should be kept closed when extinguishing the fire, and the opening other than the pressure relief port, as well as the fire valve in the fan and ventilation pipe used in the protection area should be closed before spraying seven gas propane; (5) When an external elastic door close or spring door is provided, if the opening area is not less than the calculated area of the pressure relief port, no additional pressure relief port is required. (6) The location of the installation in the protection zone should be selected to avoid being close to the heat source and direct sunlight, and be installed close to the wall. When the system is installed, it should be carried out in the following order: Place the cabinet in the position of the protection area, place the fire extinguishing agent bottle group in the cabinet, the position is back and centered, and do not produce too much impact when placed, and do not make the group dump. Connect the outlet of the container valve of the pipe assembly and the bottle group with the connecting nut. Note that to connect the outlet of the container valve, screw the connecting nut to the pipe (here it is a left-hand thread). Screw in the sealing arc surface of the connecting pipe to the bottom of the thread of the right end of the connecting nut to the basic heavy platform. 3. System debugging     System debugging: After the system is installed, the system can be debugged. Note: The solenoid valve of the gas cylinder will start when it is connected to the 24V power supply, resulting in gas spraying. Therefore, do not install the solenoid valve on the cylinder during debugging, and connect it after the system is fully debugging, fire detection and acceptance. The control panel keeps the audible and visual alarm signal during the delay period, after the delay start and after the pressure switch action signal is detected, until it is reset, so as to remind the field personnel after the system is connected normally (except the solenoid valve), and carry out a comprehensive system debugging.  
Read More
Lastest company news about Popular Science of Automatic Fire Extinguishing Systems 2023/04/27
Popular Science of Automatic Fire Extinguishing Systems
An automatic fire suppression system is one that is intended to detect fires automatically and turn on fire suppression equipment to contain or put out the fire. Typically, this kind of system consists of fire suppression equipment, control panels, and detectors.   A crucial part of automatic fire suppression systems are detectors. They have the ability to spot a fire and alert the control panel. The control panel serves as the system's main control hub, receiving signals from detectors and turning on the appropriate fire suppression device in accordance with pre-established rules. Devices for suppressing fires include automatic sprinkler systems, systems that use gas or foam to do so, and others.   The advantages of automatic fire suppression systems are that they can control fires promptly, avoiding delays and errors caused by human intervention. They can be activated immediately when a fire occurs, without the need for personnel to arrive on the scene. Additionally, automatic fire suppression systems can control or extinguish fires before they spread, reducing losses to personnel and property.   However, automatic fire suppression systems are not foolproof and have some limitations. For instance, certain types of fires may not be detected by detectors, or detectors may give false fire signals. In addition, the installation and maintenance costs of automatic fire suppression systems are relatively high, as they require regular testing and upkeep to ensure their proper functioning.     The advantages of an automatic fire suppression system include the following: Timely fire control: An automatic fire suppression system can start immediately when a fire occurs, without waiting for personnel to arrive on the scene. This can help control the fire promptly and reduce losses to personnel and property. Automation: An automatic fire suppression system is an automated system that does not require human intervention. It can start automatically when a fire occurs, greatly improving response speed and fire-fighting efficiency. High efficiency: An automatic fire suppression system can control or extinguish a fire before it spreads, thus avoiding further damage caused by the fire. Safety: An automatic fire suppression system can start automatically when a fire occurs, avoiding the risk of injury or death to personnel who would otherwise need to enter the danger zone. Reliability: An automatic fire suppression system has a high degree of reliability, can start automatically when a fire occurs, and will sound an alarm when problems are detected, providing timely maintenance and upkeep. In summary, an automatic fire suppression system can control or extinguish a fire promptly when it occurs, reducing losses to personnel and property, improving fire-fighting efficiency and safety, and has significant application value.   https://www.fm200-system.com/sale-37327211-non-polluting-fm200-mechanical-and-electrical-room-automatic-fire-extinguishing-system.html
Read More