Product Details

Place of Origin: China

Brand Name: Xingjin

Certification: CAL,CMA,CNAS,ILAC-MRA,CCC

Model Number: QMH15/80, QMH15/90

Payment & Shipping Terms

Minimum Order Quantity: 2 set system

Price: negotiation

Packaging Details: Plywood outer box with bubble bag or paper

Delivery Time: 10-15 working days

Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram

Supply Ability: 300 sets per month

Get Best Price
Product Details
Highlight:

Total Flooding IG100 Inert Gas

,

Pre-Engineered IG100 Inert Gas

,

Piping Network IG100 Inert Gas

Cylinder Volume:
80L,90L
Filling Rate:
0.178kg/L
Pattern Of Extinguishing:
Enclosed Flooding
Agent:
IG100 (100% Pressurized Nitrogen)
Max Working Pressure:
17.2Mpa
Min Working Pressure:
13.6Mpa
Color:
Red
Cylinder Volume:
80L,90L
Filling Rate:
0.178kg/L
Pattern Of Extinguishing:
Enclosed Flooding
Agent:
IG100 (100% Pressurized Nitrogen)
Max Working Pressure:
17.2Mpa
Min Working Pressure:
13.6Mpa
Color:
Red
Product Description

Pipe Network Type of IG100 Automatic Fire Suppression System

Description:

 

IG100 uses 100% pressurized nitrogen, which accounts for 78% of the atmosphere, as the extinguishing agent. Its ozone depletion potential (ODP) and  global warming potential (GWP) are zero. The atmospheric retention time is zero without any adverse effects on the environment. It fully integrates the design concept of the fire-extinguishing system in the new era, so that the product successfully has the function of environmental protection and efficient fire-fighting.

 

IG100 characteristics: protecting the ecological environment of the earth, safety and hygiene do not interfere with vision, no stain caused by extinguishing agent, durable of fire fighting effect. Nitrogen can be separated from the air and produced from a wide range of sources at a cheap charge.

 

Combined with extinguishing device and electronic accessories, the whole system can be actuated automatically. It can monitor the situation of protective region through detectors and then it can also start the extinguishing device through solenoid actuator automatically. So the whole system can achieve automation totally. Therefore, it can avoid that there is no one who notice the fire when it happens and it also saves much money for employment to supervise the protective area.

 

Management of Multiple zones is also in the safe control of the whole system. We can use one system to protect multiple zones through distributing valves. It can make the whole system alternative aiming at different protective zone. Agent can be discharged into where the fire happens. It will be very efficient to put out fire in short time. One thing that need to mention, is that a little room should be prepare to be as storage space for the whole system.Pre-Engineered IG100 Inert Gas Fire Suppression Piping Network for Total Flooding 0

Parameter:

 

Specification

Technical Parameter

Working Pressure

15Mpa

Device Model

QMD15/80

QMD15/90

Cylinder Volume

80Ltr

90Ltr

Filling Capacity of Gas

14.25kg

16.04kg

Outside Diameter of Cylinder

Φ279mm

Φ325mm

Height of Cylinder

1578+73mm

1345+60mm

Spraying Time

≤120s

Filling Rate (@200 bar)

0.178kg/L

Power

DC24V/1.6A

Nitrogen Pressure of Driving Device

6.0±1.0Mpa(20)

Condition of Reserving Room for Container

temperature: 0~50

Max. working pressure

17.2Mpa

Min. working pressure

13.6Mpa

Applications:ations:

Computer room, telecommunication room, transformer room, electrical switch and distribution room, generator room, leaching tank, drying equipment, paint spraying booth, electrical instrument room, control center, library, archives, treasure trove of cultural relics, etc.



Competitive Advantage:

1. Compared with the traditional 15MPa system, the number of fire extinguishing agent cylinders can be saved by 25%-50%.

2. The building area between cylinders is effectively reduced, and the overall occupation and utilization rate of the building are improved.

3. Constant 6MPa low pressure release can reduce the cost of pipeline and pipe fittings.

4. The constant release pressure of 6MPa provides more lasting and effective pressure, and the transmission distance can reach 200 meters.

5.The release of the whole system with low pressure can only have a less impact on personnel on sites, equipment and building structure and it is more safety.

6. The external constant pressure reliever can only bear the pressure when the system is spraying, which is convenient for dis-assembly and maintenance and effectively reduces the failure rate of the system.

7. After spraying, the system does not need to replace any parts, simple dis-assembly and secondary filling, the system can be quickly put into operation.

8. The opening area of the pressure-relief device is reduced. the input cost of the pressure-relief device is directly reduced, and the safety buckle is installed and arranged more simply.

9. Nitrogen fire extinguishing system(IG-100) can be widely used to make rapid response to fire, protect staffs on sites, sudden fire, important places sensitive to chemical reaction and effectively protect the safety of personnel and property.

Working principle:

Here is the illustration of working principle to whole system

 Pre-Engineered IG100 Inert Gas Fire Suppression Piping Network for Total Flooding 1





 

Simulated diagram:

 Below attached is one mimic diagram of piped network type of IG100 nitrogen automatic fire suppression system.

Pre-Engineered IG100 Inert Gas Fire Suppression Piping Network for Total Flooding 2
Pre-Engineered IG100 Inert Gas Fire Suppression Piping Network for Total Flooding 3